| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Multiple hardcoded credentials have been identified, which are allowed to sign-in to the exos 9300 datapoint server running on port 1004 and 1005. This server is used for relaying status information from and to the Access Managers. This information, among other things, is used to graphically visualize open doors and alerts. However, controlling the Access Managers via this interface is also possible.
To send and receive status information, authentication is necessary. The Kaba exos 9300 application contains hard-coded credentials for four different users, which are allowed to login to the datapoint server and receive as well as send information, including commands to open arbitrary doors. |
| CWE-798: Use of Hard-coded Credentials |
| All the Toshiba printers contain a shell script using the same hardcoded key to encrypt logs. An attacker can decrypt the encrypted files using the hardcoded key. This vulnerability can be executed in combination with other vulnerabilities and difficult to execute alone. So, the CVSS score for this vulnerability alone is lower than the score listed in the "Base Score" of this vulnerability. For detail on related other vulnerabilities, please ask to the below contact point.
https://www.toshibatec.com/contacts/products/
As for the affected products/models/versions, see the reference URL. |
| This vulnerability exists in ZKTeco WL20 due to hard-coded MQTT credentials and endpoints stored in plaintext within the device firmware. An attacker with physical access could exploit this vulnerability by extracting the firmware and analyzing the binary data to retrieve the hard-coded MQTT credentials and endpoints from the targeted device.
Successful exploitation of this vulnerability could allow the attacker to gain unauthorized access to the MQTT broker and manipulate the communications of the targeted device. |
| UNI-NMS-Lite uses hard-coded credentials that could allow an
unauthenticated attacker to gain administrative privileges to all
UNI-NMS managed devices. |
| Hardcoded credentials vulnerability in Trellix ePolicy Orchestrator (ePO) on Premise prior to 5.10 Service Pack 1 Update 2 allows an attacker with admin privileges on the ePO server to read the contents of the orion.keystore file, allowing them to access the ePO database encryption key. This was possible through using a hard coded password for the keystore. Access Control restrictions on the file mean this would not be exploitable unless the user is the system admin for the server that ePO is running on. |
| Hardcoded credentials in gsigel14 ATLAS-EPIC commit f29312c (2025-05-26). |
| Cypress Solutions CTM-200/CTM-ONE 1.3.6 contains hard-coded credentials vulnerability in Linux distribution that exposes root access. Attackers can exploit the static 'Chameleon' password to gain remote root access via Telnet or SSH on affected devices. |
| An issue in H3C Device R365V300R004 allows a remote attacker to execute arbitrary code via the default password. NOTE: the Supplier's position is that their "product lines enforce or clearly prompt users to change any initial credentials upon first use. At most, this would be a case of misconfiguration if an administrator deliberately ignored the prompts, which is outside the scope of CVE definitions." |
| A hardcoded AES key in PMFW may result in a privileged attacker gaining access to the key, potentially resulting in internal debug information leakage. |
| The SunPower PVS6's BluetoothLE interface is vulnerable due to its use of hardcoded encryption parameters and publicly accessible protocol details. An attacker within Bluetooth range could exploit this vulnerability to gain full access to the device's servicing interface. This access allows the attacker to perform actions such as firmware replacement, disabling power production, modifying grid settings, creating SSH tunnels, altering firewall settings, and manipulating connected devices. |
| Arcade MCP allows you to to create, deploy, and share MCP Servers. Prior to 1.5.4, the arcade-mcp HTTP server uses a hardcoded default worker secret ("dev") that is never validated or overridden during normal server startup. As a result, any unauthenticated attacker who knows this default key can forge valid JWTs and fully bypass the FastAPI authentication layer. This grants remote access to all worker endpoints—including tool enumeration and tool invocation—without credentials. This vulnerability is fixed in 1.5.4. |
| In KDE libksieve before 23.03.80, kmanagesieve/session.cpp places a cleartext password in server logs because a username variable is accidentally given a password value. |
| 'OfferBox' App for Android versions 2.0.0 to 2.3.17 and 'OfferBox' App for iOS versions 2.1.7 to 2.6.14 use a hard-coded secret key for JWT. Secret key for JWT may be retrieved if the application binary is reverse-engineered. |
| UNI-NMS-Lite uses hard-coded credentials that could allow an
unauthenticated attacker to read, manipulate and create entries in the
managed database. |
| Insufficient hardening of the proxyuser account in the AiKaan IoT management platform, combined with the use of a shared, hardcoded SSH private key, allows remote attackers to authenticate to the cloud controller, gain interactive shell access, and pivot into other connected IoT devices. This can lead to remote code execution, information disclosure, and privilege escalation across customer environments. |
| Ubiquiti U7-Pro 7.0.35 was discovered to contain a hardcoded password vulnerability in /etc/shadow, which allows attackers to log in as root. NOTE: this is disputed by the Supplier because the observation only established that a password is present in a firmware image; however, the device cannot be deployed without setting a new password during installation. |
| Array Networks vAPV (version 8.3.2.17) and vxAG (version 9.2.0.34) appliances are affected by a privilege escalation vulnerability caused by a combination of hardcoded SSH credentials (or SSH private key) and insecure permissions on a startup script. The devices ship with a default SSH login or a hardcoded DSA private key, allowing an attacker to authenticate remotely with limited privileges.
Once authenticated, an attacker can overwrite the world-writable /ca/bin/monitor.sh script with arbitrary commands. Since this script is executed with elevated privileges through the backend binary, enabling the debug monitor via backend -c "debug monitor on" triggers execution of the attacker's payload as root. This allows full system compromise. |
| Clinic Image System developed by Changing contains hard-coded Credentials, allowing unauthenticated remote attackers to log into the system using administrator credentials embedded in the source code. |
| Certain Draytek products are affected by Insecure Configuration. This affects AP903 v1.4.18 and AP912C v1.4.9 and AP918R v1.4.9. The setting of the password property in the ripd.conf configuration file sets a hardcoded weak password, posing a security risk. An attacker with network access could exploit this to gain unauthorized control over the routing daemon, potentially altering network routes or intercepting traffic. |