| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The FTP server on the Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware through 1.60 IR 04 has hardcoded credentials, which makes it easier for remote attackers to obtain access via an FTP session. |
| Phoenix Contact ProConOs and MultiProg do not require authentication, which allows remote attackers to execute arbitrary commands via protocol-compliant traffic. |
| A vulnerability was identified in Cudy LT500E up to 2.3.12. Affected is an unknown function of the file /squashfs-root/etc/shadow of the component Web Interface. The manipulation leads to use of hard-coded password. The attack must be carried out locally. The attack's complexity is rated as high. The exploitability is told to be difficult. The exploit is publicly available and might be used. Upgrading to version 2.3.13 is able to address this issue. It is recommended to upgrade the affected component. The vendor explains: "[T]he firmware does store a default password of 'admin'. This password has been deprecated since LT500E firmware version 2.3.13 and is no longer used. The LT500E does not have an administrator password set by default; a new password (at least 8 characters ) must be manually created upon first login the web management page." |
| A vulnerability was found in Intelbras InControl up to 2.21.59. It has been classified as problematic. Affected is an unknown function of the component Dispositivos Edição Page. The manipulation of the argument Senha de Comunicação leads to unprotected storage of credentials. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. According to the vendor this issue should be fixed in a later release. |
| A vulnerability, which was classified as problematic, was found in D-Link DCS-7517 up to 2.02.0. This affects the function g_F_n_GenPassForQlync of the file /bin/httpd of the component Qlync Password Generation Handler. The manipulation leads to use of hard-coded password. It is possible to initiate the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer. |
| The Carlo Gavazzi
EOS-Box
stores hard-coded passwords in the PHP file of
the device. By using the hard-coded passwords, attackers can log into
the device with administrative privileges. This could allow the attacker
to have unauthorized access. |
| WellinTech KingSCADA 3.0 uses a cleartext base64 format for storage of passwords in user.db, which allows context-dependent attackers to obtain sensitive information by reading this file. |
| The potential exists for exposure of the product's password used to restrict unauthorized access to Rockwell PLC5/SLC5/0x/RSLogix 1785-Lx and 1747-L5x controllers. The potential exists for an unauthorized programming and configuration client to gain access to the product and allow changes to the product’s configuration or program. When applicable, upgrade product firmware to a version that includes enhanced security functionality compatible with Rockwell Automation's FactoryTalk Security services. |
| A vulnerability, which was classified as problematic, has been found in TOTOLINK T10 4.1.8cu.5207. Affected by this issue is some unknown functionality of the file /etc/shadow.sample. The manipulation leads to use of hard-coded password. The attack can only be initiated within the local network. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. |
| The PAM module for fscrypt doesn't adequately validate fscrypt metadata files, allowing users to create malicious metadata files that prevent other users from logging in. A local user can cause a denial of service by creating a fscrypt metadata file that prevents other users from logging into the system. We recommend upgrading to version 0.3.3 or above |
| Versions of VASA Provider for Clustered Data ONTAP prior to 7.0P1 contain a web server that accepts plain text authentication. This could allow an unauthenticated attacker to obtain authentication credentials. |
| An issue was discovered in Becton, Dickinson and Company (BD) Alaris 8015 Point of Care (PC) unit, Version 9.5 and prior versions, and Version 9.7, and 8000 PC unit. An unauthorized user with physical access to an affected Alaris PC unit may be able to obtain unencrypted wireless network authentication credentials and other sensitive technical data by disassembling the PC unit and accessing the device's flash memory. The Alaris 8015 PC unit, Version 9.7, and the 8000 PC unit store wireless network authentication credentials and other sensitive technical data on internal flash memory. Accessing the internal flash memory of the affected device would require special tools to extract data and carrying out this attack at a healthcare facility would increase the likelihood of detection. |
| An issue was discovered in Siemens SICAM PAS before 8.00. Because of Storing Passwords in a Recoverable Format, an authenticated local attacker with certain privileges could possibly reconstruct the passwords of users for accessing the database. |
| FreeIPA uses a default password policy that locks an account after 5 unsuccessful authentication attempts, which allows remote attackers to cause a denial of service by locking out the account in which system services run on. |
| An information disclosure vulnerability in the Core and Management Console in BlackBerry Enterprise Server (BES) 12 through 12.5.2 allows remote attackers to obtain local or domain credentials of an administrator or user account by sniffing traffic between the two elements during a login attempt. |
| Wi-Fi STATION L-02F Software version V10g and earlier allows remote attackers to access the device with administrative privileges and perform unintended operations through a backdoor account. |
| IBM BigFix Inventory 9.2 does not require that users should have strong passwords by default, which makes it easier for attackers to compromise user accounts. IBM X-Force ID: 118851. |
| Information Disclosure can occur in encryptionProfiles.jsd in Hitek Software's Automize because of the Read attribute being set for Users. This allows an attacker to recover encrypted passwords for GPG Encryption profiles. Verified in all 10.x versions up to and including 10.25, and all 11.x versions up to and including 11.14. |
| SeaWell Networks Spectrum SDC 02.05.00 has a default password of "admin" for the "admin" account. |
| WAGO IO 750-849 01.01.27 and 01.02.05, WAGO IO 750-881, and WAGO IO 758-870 have weak credential management. |