Search Results (15641 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-10498 1 Schneider-electric 1 Powerlogic Hdpm6000 2026-04-15 6.5 Medium
CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could allow an unauthorized attacker to modify configuration values outside of the normal range when the attacker sends specific Modbus write packets to the device which could result in invalid data or loss of web interface functionality.
CVE-2024-36292 2026-04-15 7.3 High
Improper buffer restrictions for some Intel(R) Data Center GPU Flex Series for Windows driver before version 31.0.101.4314 may allow an authenticated user to potentially enable denial of service via local access.
CVE-2024-4162 2026-04-15 4.4 Medium
A buffer error in Panasonic KW Watcher versions 1.00 through 2.83 may allow attackers malicious read access to memory.
CVE-2025-9020 1 Dronecode 1 Px4 Drone Autopilot 2026-04-15 4.5 Medium
A vulnerability was found in PX4 PX4-Autopilot up to 1.15.4. This issue affects the function MavlinkReceiver::handle_message_serial_control of the file src/modules/mavlink/mavlink_receiver.cpp of the component Mavlink Shell Closing Handler. The manipulation of the argument _mavlink_shell leads to use after free. An attack has to be approached locally. The complexity of an attack is rather high. The exploitation is known to be difficult. The identifier of the patch is 4395d4f00c49b888f030f5b43e2a779f1fa78708. It is recommended to apply a patch to fix this issue.
CVE-2023-48267 2026-04-15 7.9 High
Improper buffer restrictions in some Intel(R) System Security Report and System Resources Defense firmware may allow a privileged user to potentially enable escalation of privilege via local access.
CVE-2025-61481 1 Mikrotik 2 Routeros, Switchos 2026-04-15 10 Critical
An issue in MikroTik RouterOS v.7.14.2 and SwOS v.2.18 exposes the WebFig management interface over cleartext HTTP by default, allowing an on-path attacker to execute injected JavaScript in the administrator’s browser and intercept credentials.
CVE-2025-1960 2026-04-15 9.8 Critical
CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could cause an attacker to execute unauthorized commands when a system’s default password credentials have not been changed on first use. The default username is not displayed correctly in the WebHMI interface.
CVE-2025-26503 1 Windriver 1 Vxworks 2026-04-15 6.7 Medium
A crafted system call argument can cause memory corruption.
CVE-2024-46547 2026-04-15 7.5 High
A vulnerability was found in Romain Bourdon Wampserver all versions (discovered in v3.2.3 and v3.2.6) where unauthorized users could access sensitive information due to improper access control validation via PHP Info Page. This issue can lead to data leaks.
CVE-2025-10824 1 Axboe 1 Fio 2026-04-15 5.3 Medium
A vulnerability was determined in axboe fio up to 3.41. This impacts the function __parse_jobs_ini of the file init.c. Executing manipulation can lead to use after free. The attack needs to be launched locally. The exploit has been publicly disclosed and may be utilized.
CVE-2025-36625 1 Tenable 1 Nessus 2026-04-15 4.3 Medium
In Nessus versions prior to 10.8.4, a non-authenticated attacker could alter Nessus logging entries by manipulating http requests to the application.
CVE-2024-0179 2026-04-15 8.2 High
SMM Callout vulnerability within the AmdCpmDisplayFeatureSMM driver could allow locally authenticated attackers to overwrite SMRAM, potentially resulting in arbitrary code execution.
CVE-2024-4231 2026-04-15 4.6 Medium
This vulnerability exists in Digisol Router (DG-GR1321: Hardware version 3.7L; Firmware version : v3.2.02) due to presence of root terminal access on a serial interface without proper access control. An attacker with physical access could exploit this by identifying UART pins and accessing the root shell on the vulnerable system. Successful exploitation of this vulnerability could allow the attacker to access the sensitive information on the targeted system.
CVE-2024-41975 2026-04-15 5.3 Medium
An unauthenticated remote attacker can gain limited information of the PLC network but the user management of the PLCs prevents the actual access to the PLCs.
CVE-2025-26408 2026-04-15 6.1 Medium
The JTAG interface of Wattsense Bridge devices can be accessed with physical access to the PCB. After connecting to the interface, full access to the device is possible. This enables an attacker to extract information, modify and debug the device's firmware. All known versions are affected.
CVE-2025-11015 1 Ogrecave 1 Ogre 2026-04-15 5.3 Medium
A weakness has been identified in OGRECave Ogre up to 14.4.1. Impacted is the function STBIImageCodec::encode of the file /ogre/PlugIns/STBICodec/src/OgreSTBICodec.cpp. This manipulation causes mismatched memory management routines. The attack is restricted to local execution. The exploit has been made available to the public and could be exploited.
CVE-2025-0607 1 Logo Software 1 Logo Cloud 2026-04-15 4.3 Medium
Improper Encoding or Escaping of Output vulnerability in Logo Software Inc. Logo Cloud allows Phishing.This issue affects Logo Cloud: before 2.57.
CVE-2023-6484 1 Redhat 3 Build Keycloak, Red Hat Single Sign On, Rhosemc 2026-04-15 5.3 Medium
A log injection flaw was found in Keycloak. A text string may be injected through the authentication form when using the WebAuthn authentication mode. This issue may have a minor impact to the logs integrity.
CVE-2024-23980 2026-04-15 7.5 High
Improper buffer restrictions in PlatformPfrDxe driver in UEFI firmware for some Intel(R) Server D50FCP Family products may allow a privileged user to enable escalation of privilege via local access.
CVE-2025-62877 1 Suse 1 Harvester 2026-04-15 9.8 Critical
Projects using the SUSE Virtualization (Harvester) environment may expose the OS default ssh login password  if they are using the 1.5.x or 1.6.x interactive installer to either create a new cluster or add new hosts to an existing cluster. The environment is not affected if the PXE boot mechanism is utilized along with the Harvester configuration setup.