Search Results (4547 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-8070 2026-04-15 8.5 High
CWE-312: Cleartext Storage of Sensitive Information vulnerability exists that exposes test credentials in the firmware binary
CVE-2024-8059 2026-04-15 4.3 Medium
IPMI credentials may be captured in XCC audit log entries when the account username length is 16 characters.
CVE-2025-32353 2026-04-15 8.2 High
Kaseya Rapid Fire Tools Network Detective 2.0.16.0 has Unencrypted Credentials (for privileged access) stored in the collector.txt configuration file.
CVE-2025-52351 2026-04-15 8.8 High
Aikaan IoT management platform v3.25.0325-5-g2e9c59796 sends a newly generated password to users in plaintext via email and also includes the same password as a query parameter in the account activation URL (e.g., https://domain.com/activate=xyz). This practice can result in password exposure via browser history, proxy logs, referrer headers, and email caching. The vulnerability impacts user credential confidentiality during initial onboarding.
CVE-2025-27722 2026-04-15 5.9 Medium
Cleartext transmission of sensitive information issue exists in Wi-Fi AP UNIT 'AC-WPS-11ac series'. If exploited, a man-in-the-middle attack may allow a remote unauthenticated attacker to eavesdrop the communication and obtain the authentication information.
CVE-2025-7215 1 Fnkvision 1 Fnk-gu2 2026-04-15 1.6 Low
A vulnerability, which was classified as problematic, has been found in FNKvision FNK-GU2 up to 40.1.7. Affected by this issue is some unknown functionality of the file /rom/wpa_supplicant.conf. The manipulation leads to cleartext storage of sensitive information. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used.
CVE-2025-1243 2026-04-15 N/A
The Temporal api-go library prior to version 1.44.1 did not send `update response` information to Data Converter when the proxy package within the api-go module was used in a gRPC proxy prior to transmission. This resulted in information contained within the `update response` field not having Data Converter transformations (e.g. encryption) applied. This is an issue only when using the UpdateWorkflowExecution APIs (released on 13th January 2025) with a proxy leveraging the api-go library before version 1.44.1. Other data fields were correctly sent to Data Converter. This issue does not impact the Data Converter server. Data was encrypted in transit. Temporal Cloud services are not impacted.
CVE-2025-4053 2026-04-15 N/A
The data stored in Be-Tech Mifare Classic card is stored in cleartext. An attacker having access to a Be-Tech hotel guest Mifare Classic card can create a master key card that unlocks all the locks in the building. This issue affects all Be-Tech Mifare Classic card systems. To fix the vulnerability, it is necessary to replace the software, encoder, cards, and PCBs in the locks.
CVE-2025-54799 1 Lego Project 1 Lego 2026-04-15 5.3 Medium
Let's Encrypt client and ACME library written in Go (Lego). In versions 4.25.1 and below, the github.com/go-acme/lego/v4/acme/api package (thus the lego library and the lego cli as well) don't enforce HTTPS when talking to CAs as an ACME client. Unlike the http-01 challenge which solves an ACME challenge over unencrypted HTTP, the ACME protocol requires HTTPS when a client communicates with the CA to performs ACME functions. However, the library fails to enforce HTTPS both in the original discover URL (configured by the library user) and in the subsequent addresses returned by the CAs in the directory and order objects. If users input HTTP URLs or CAs misconfigure endpoints, protocol operations occur over HTTP instead of HTTPS. This compromises privacy by exposing request/response details like account and request identifiers to network attackers. This was fixed in version 4.25.2.
CVE-2025-40753 1 Siemens 2 Q100, Q200 2026-04-15 6.2 Medium
A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices export the password for the SMTP account as plain text in the Configuration File. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes.
CVE-2024-33471 2026-04-15 7.2 High
An issue in the Sensor Settings of AVTECH Room Alert 4E v4.4.0 allows attackers to gain access to SMTP credentials in plaintext via a crafted AJAX request. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.
CVE-2024-4540 1 Redhat 3 Build Keycloak, Red Hat Single Sign On, Rhosemc 2026-04-15 7.5 High
A flaw was found in Keycloak in OAuth 2.0 Pushed Authorization Requests (PAR). Client-provided parameters were found to be included in plain text in the KC_RESTART cookie returned by the authorization server's HTTP response to a `request_uri` authorization request, possibly leading to an information disclosure vulnerability.
CVE-2024-36426 1 Targit 1 Decision Suite 23.2.15007.0 2026-04-15 7.5 High
In TARGIT Decision Suite 23.2.15007.0 before Autumn 2023, the session token is part of the URL and may be sent in a cleartext HTTP session.
CVE-2023-49341 2026-04-15 7.5 High
An issue was discovered in Newland Nquire 1000 Interactive Kiosk version NQ1000-II_G_V1.00.011, allows remote attackers to obtain sensitive information via cleartext credential storage in backup.htm component.
CVE-2024-50624 1 Kde 1 Kmail 2026-04-15 5.9 Medium
ispdbservice.cpp in KDE Kmail before 6.2.0 allows man-in-the-middle attackers to trigger use of an attacker-controlled mail server because cleartext HTTP is used for a URL such as http://autoconfig.example.com or http://example.com/.well-known/autoconfig for retrieving the configuration. This is related to kmail-account-wizard.
CVE-2025-2181 1 Paloaltonetworks 1 Checkov 2026-04-15 N/A
A sensitive information disclosure vulnerability in Palo Alto Networks Checkov by Prisma® Cloud can result in the cleartext exposure of Prisma Cloud access keys in Checkov's output.
CVE-2024-10973 1 Redhat 3 Build Keycloak, Jboss Enterprise Application Platform, Jbosseapxp 2026-04-15 5.7 Medium
A vulnerability was found in Keycloak. The environment option `KC_CACHE_EMBEDDED_MTLS_ENABLED` does not work and the JGroups replication configuration is always used in plain text which can allow an attacker that has access to adjacent networks related to JGroups to read sensitive information.
CVE-2025-53703 2026-04-15 7.5 High
DuraComm SPM-500 DP-10iN-100-MU transmits sensitive data without encryption over a channel that could be intercepted by attackers.
CVE-2025-41458 2026-04-15 5.5 Medium
Unencrypted storage in the database in Two App Studio Journey v5.5.9 for iOS allows local attackers to extract sensitive data via direct access to the app’s filesystem.
CVE-2024-12094 1 Mogify Infotech 1 Tinxy Mobile App 2026-04-15 N/A
This vulnerability exists in the Tinxy mobile app due to storage of logged-in user information in plaintext on the device database. An attacker with physical access to the rooted device could exploit this vulnerability by accessing its database leading to unauthorized access of user information such as username, email address and mobile number. Note: To exploit this vulnerability, the device must be rooted/jailbroken.