CVE-2024-10944 1 Rockwellautomation 1 Factorytalk Updater 2026-04-15 8.4 High
A Remote Code Execution vulnerability exists in the affected product. The vulnerability requires a high level of permissions and exists due to improper input validation resulting in the possibility of a malicious Updated Agent being deployed.
CVE-2025-13824 1 Rockwellautomation 3 Micro820, Micro850, Micro870 2026-04-15 N/A
A security issue exists due to improper handling of malformed CIP packets during fuzzing. The controller enters a hard fault with solid red Fault LED and becomes unresponsive. Upon power cycle, the controller will enter recoverable fault where the MS LED and Fault LED become flashing red and reports fault code 0xF019. To recover, clear the fault.
CVE-2024-6079 1 Rockwellautomation 1 Emulate3d 2026-04-15 N/A
A vulnerability exists in the Rockwell Automation Emulate3D™, which could be leveraged to execute a DLL Hijacking attack. The application loads shared libraries, which are readable and writable by any user. If exploited, a malicious user could leverage a malicious dll and perform a remote code execution attack.
CVE-2025-7693 1 Rockwellautomation 1 Micro800 2026-04-15 N/A
A security issue exists due to improper handling of malformed CIP Forward Close packets during fuzzing. The controller enters a solid red Fault LED state and becomes unresponsive. Upon power cycle, the controller will enter recoverable fault where the MS LED and Fault LED become flashing red and reports fault code 0xF015. To recover, clear the fault.
CVE-2025-11084 1 Rockwellautomation 1 Factorytalk 2026-04-15 N/A
A security issue exists within DataMosaix™ Private Cloud, allowing attackers to bypass MFA during setup and obtain a valid login-token cookie without knowing the users password. This vulnerability occurs when MFA is enabled but not completed within a 7-day period.
CVE-2025-9177 1 Rockwellautomation 1 1715-aentr Ethernet/ip Adapter 2026-04-15 N/A
A denial-of-service security issue exists in the affected product and version. The security issue stems from a high number of requests sent to the web server. This could result in a web server crash however; this does not impact I/O control or communication . A power cycle is required to recover and utilize the webpage.
CVE-2025-11696 1 Rockwellautomation 1 Studio 5000 Simulation Interface 2026-04-15 N/A
A local server-side request forgery (SSRF) security issue exists within Studio 5000® Simulation Interface™ via the API. This vulnerability allows any Windows user on the system to trigger outbound SMB requests, enabling the capture of NTLM hashes.
CVE-2019-25276 1 Rockwellautomation 2 Factorytalk Activation, Studio 2026-04-15 7.8 High
Studio 5000 Logix Designer 30.01.00 contains an unquoted service path vulnerability in the FactoryTalk Activation Service that allows local users to potentially execute code with elevated privileges. Attackers can exploit the unquoted path in C:\Program Files (x86)\Rockwell Software\FactoryTalk Activation\ to inject malicious code that would execute with LocalSystem permissions.
CVE-2025-12807 1 Rockwellautomation 1 Factorytalk Datamosaix Private Cloud 2026-04-15 N/A
A security issue was discovered in DataMosaix Private Cloud, allowing users with low privilege to perform sensitive database operations through exposed API endpoints.
CVE-2024-10945 1 Rockwellautomation 1 Factorytalk Updater 2026-04-15 7.3 High
A Local Privilege Escalation vulnerability exists in the affected product. The vulnerability requires a local, low privileged threat actor to replace certain files during update and exists due to a failure to perform proper security checks before installation.
CVE-2025-14376 1 Rockwellautomation 1 Verve Asset Manager 2026-04-15 N/A
A security issue was discovered within the legacy ADI server component of Verve Asset Manager, caused by plaintext secrets stored in environment variables on the ADI server. This component has been retired and has been optional since the 1.36 release in 2024.
CVE-2025-7774 1 Rockwellautomation 1 Armorblock 5000 Io 2026-04-15 N/A
A security issue exists within the 5032 16pt Digital Configurable module’s web server. Intercepted session credentials can be used within a 3-minute timeout window, allowing unauthorized users to perform privileged actions.
CVE-2025-9368 1 Rockwellautomation 1 432es-ig3 Series A 2026-04-15 N/A
A security issue exists within 432ES-IG3 Series A, which affects GuardLink® EtherNet/IP Interface, resulting in denial-of-service. A manual power cycle is required to recover the device.
CVE-2025-9036 1 Rockwellautomation 1 Factorytalk Action Manager 2026-04-15 N/A
A security issue in the runtime event system allows unauthenticated connections to receive a reusable API token. This token is broadcasted over a WebSocket and can be intercepted by any local client listening on the connection.
CVE-2025-7350 1 Rockwellautomation 1 Stratix 2026-04-15 N/A
A security issue affecting multiple Cisco devices also directly impacts Stratix® 5410, 5700, and 8000 devices. This can lead to remote code execution by uploading and running malicious configurations without authentication.
CVE-2025-9437 1 Rockwellautomation 1 Armorstart Aop 2026-04-15 N/A
A security issue exists within the Studio 5000 Logix Designer add-on profile (AOP) for the ArmorStart Classic distributed motor controller, resulting in denial-of-service. This vulnerability is possible due to the input of invalid values into Component Object Model (COM) methods.
CVE-2025-11085 1 Rockwellautomation 1 Factorytalk 2026-04-15 N/A
A security issue exists within DataMosaix™ Private Cloud allowing for Persistent XSS. This vulnerability can result in the execution of malicious JavaScript, allowing for account takeover, credential theft, or redirection to a malicious website.
CVE-2025-9041 1 Rockwellautomation 1 Flex 5000 Io 2026-04-15 N/A
A security issue exists due to improper handling of CIP Class 32’s request when a module is inhibited on the 5094-IF8 device. It causes the module to enter a fault state with the Module LED flashing red. Upon un-inhibiting, the module returns a connection fault (Code 16#0010), and the module cannot recover without a power cycle.
CVE-2025-13823 1 Rockwellautomation 3 Micro820, Micro850, Micro870 2026-04-15 N/A
A security issue was found in the IPv6 stack in the Micro850 and Micro870 controllers when the controllers received multiple malformed packets during fuzzing. The controllers will go into recoverable fault with fault code 0xFE60. To recover the controller, clear the fault.
CVE-2025-7353 1 Rockwellautomation 1 Controllogix 2026-04-15 N/A