Search Results (317 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-32965 1 Silextechnology 3 Amc Manager, Sd-330ac, Sd-330ac Firmware 2026-04-22 7.5 High
Initialization of a resource with an insecure default vulnerability exists in SD-330AC and AMC Manager provided by silex technology, Inc. When the affected device is connected to the network with the initial (factory-default) configuration, the device can be configured with the null string password.
CVE-2025-13357 1 Hashicorp 1 Terraform Provider 2026-04-20 7.4 High
Vault’s Terraform Provider incorrectly set the default deny_null_bind parameter for the LDAP auth method to false by default, potentially resulting in an insecure configuration. If the underlying LDAP server allowed anonymous or unauthenticated binds, this could result in authentication bypass. This vulnerability, CVE-2025-13357, is fixed in Vault Terraform Provider v5.5.0.
CVE-2026-2617 1 Beetel 2 777vr1, 777vr1 Firmware 2026-04-18 6.3 Medium
A vulnerability was found in Beetel 777VR1 up to 01.00.09. This affects an unknown function of the component Telnet Service/SSH Service. The manipulation results in insecure default initialization of resource. The attack can only be performed from the local network. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-25499 1 Bpg 2 Terraform-provider-proxmox, Terraform Provider 2026-04-17 7.5 High
Terraform / OpenTofu Provider adds support for Proxmox Virtual Environment. Prior to version 0.93.1, in the SSH configuration documentation, the sudoer line suggested is insecure and can result in escaping the folder using ../, allowing any files on the system to be edited. This issue has been patched in version 0.93.1.
CVE-2026-25894 1 Frangoteam 1 Fuxa 2026-04-17 9.8 Critical
FUXA is a web-based Process Visualization (SCADA/HMI/Dashboard) software. An insecure default configuration in FUXA allows an unauthenticated, remote attacker to gain administrative access and execute arbitrary code on the server. This affects FUXA through version 1.2.9 when authentication is enabled, but the administrator JWT secret is not configured. This issue has been patched in FUXA version 1.2.10.
CVE-2026-23116 1 Linux 1 Linux Kernel 2026-04-17 5.5 Medium
In the Linux kernel, the following vulnerability has been resolved: pmdomain: imx8m-blk-ctrl: Remove separate rst and clk mask for 8mq vpu For i.MX8MQ platform, the ADB in the VPUMIX domain has no separate reset and clock enable bits, but is ungated and reset together with the VPUs. So we can't reset G1 or G2 separately, it may led to the system hang. Remove rst_mask and clk_mask of imx8mq_vpu_blk_ctl_domain_data. Let imx8mq_vpu_power_notifier() do really vpu reset.
CVE-2026-28775 2 Datacast, International Datacasting Corporation (idc) 3 Sfx2100, Sfx2100 Firmware, Sfx2100 Series Superflex Satellitereceiver 2026-04-17 9.8 Critical
An unauthenticated Remote Code Execution (RCE) vulnerability exists in the SNMP service of International Datacasting Corporation (IDC) SFX Series SuperFlex SatelliteReceiver. The deployment insecurely provisions the `private` SNMP community string with read/write access by default. Because the SNMP agent runs as root, an unauthenticated remote attacker can utilize `NET-SNMP-EXTEND-MIB` directives, abusing the fact that the system runs a vulnerable version of net-snmp pre 5.8, to execute arbitrary operating system commands with root privileges.
CVE-2026-1675 1 Wordpress 1 Wordpress 2026-04-15 5.3 Medium
The Advanced Country Blocker plugin for WordPress is vulnerable to Authorization Bypass in all versions up to, and including, 2.3.1 due to the use of a predictable default value for the secret bypass key created during installation without requiring users to change it. This makes it possible for unauthenticated attackers to bypass the geolocation blocking mechanism by appending the key to any URL on sites where the administrator has not changed the default value.
CVE-2026-26122 1 Microsoft 2 Aci Confidential Containers, Microsoft Aci Confidential Containers 2026-04-15 6.5 Medium
Initialization of a resource with an insecure default in Azure Compute Gallery allows an authorized attacker to disclose information over a network.
CVE-2026-34780 2 Electron, Electronjs 2 Electron, Electron 2026-04-15 8.4 High
Electron is a framework for writing cross-platform desktop applications using JavaScript, HTML and CSS. From versions 39.0.0-alpha.1 to before 39.8.0, 40.0.0-alpha.1 to before 40.7.0, and 41.0.0-alpha.1 to before 41.0.0-beta.8, apps that pass VideoFrame objects (from the WebCodecs API) across the contextBridge are vulnerable to a context isolation bypass. An attacker who can execute JavaScript in the main world (for example, via XSS) can use a bridged VideoFrame to gain access to the isolated world, including any Node.js APIs exposed to the preload script. Apps are only affected if a preload script returns, resolves, or passes a VideoFrame object to the main world via contextBridge.exposeInMainWorld(). Apps that do not bridge VideoFrame objects are not affected. This issue has been patched in versions 39.8.0, 40.7.0, and 41.0.0-beta.8.
CVE-2018-25193 1 Cesanta 1 Mongoose Web Server 2026-04-15 7.5 High
Mongoose Web Server 6.9 contains a denial of service vulnerability that allows remote attackers to crash the service by establishing multiple socket connections. Attackers can repeatedly create connections to the default port and send malformed data to exhaust server resources and cause service unavailability.
CVE-2018-25169 2 Ampps, Softaculous 2 Ampps, Ampps 2026-04-15 7.5 High
AMPPS 2.7 contains a denial of service vulnerability that allows remote attackers to crash the service by sending malformed data to the default HTTP port. Attackers can establish multiple socket connections and transmit invalid payloads to exhaust server resources and cause service unavailability.
CVE-2025-1960 2026-04-15 9.8 Critical
CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could cause an attacker to execute unauthorized commands when a system’s default password credentials have not been changed on first use. The default username is not displayed correctly in the WebHMI interface.
CVE-2023-31325 1 Amd 6 Radeon, Radeon Pro W7000, Radeon Rx 7000 and 3 more 2026-04-15 7.2 High
Improper isolation of shared resources on System-on-a-chip (SOC) could a privileged attacker to tamper with the contents of the PSP reserved DRAM region potentially resulting in loss of confidentiality and integrity.
CVE-2024-25972 1 Atsumi 1 Oet-213h-bts1 2026-04-15 8.3 High
Initialization of a resource with an insecure default vulnerability in OET-213H-BTS1 sold in Japan by Atsumi Electric Co., Ltd. allows a network-adjacent unauthenticated attacker to configure and control the affected product.
CVE-2025-54514 1 Amd 10 Epyc 9005 Series Processors, Epyc Embedded 9005 Series Processors, Ryzen 5000 Series Desktop Processors and 7 more 2026-04-15 N/A
Improper isolation of shared resources on a system on a chip by a malicious local attacker with high privileges could potentially lead to a partial loss of integrity.
CVE-2024-41995 1 Ricoh Company Ltd 1 Javatm Platform 2026-04-15 7.5 High
Initialization of a resource with an insecure default vulnerability exists in JavaTM Platform Ver.12.89 and earlier. If this vulnerability is exploited, the product may be affected by some known TLS1.0 and TLS1.1 vulnerabilities. As for the specific products/models/versions of MFPs and printers that contain JavaTM Platform, see the information provided by the vendor.
CVE-2025-41713 1 Wago 1 Cc100 2026-04-15 6.5 Medium
During a short time frame while the device is booting an unauthenticated remote attacker can send traffic to unauthorized networks due to the switch operating in an undefined state until a CPU-induced reset allows proper configuration.
CVE-2025-62877 1 Suse 1 Harvester 2026-04-15 9.8 Critical
Projects using the SUSE Virtualization (Harvester) environment may expose the OS default ssh login password  if they are using the 1.5.x or 1.6.x interactive installer to either create a new cluster or add new hosts to an existing cluster. The environment is not affected if the PXE boot mechanism is utilized along with the Harvester configuration setup.
CVE-2025-31930 2026-04-15 8.8 High
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger.