| WHILL Model C2 Electric Wheelchairs and Model F Power Chairs do not enforce authentication for Bluetooth connections. An attacker within range can pair with the device and issue movement commands, override speed restrictions, and manipulate configuration profiles without any credentials or user interaction. |
| An unrestricted file upload vulnerability exists in Dell (acquired by Quest) KACE K1000 System Management Appliance version 5.0 - 5.3, 5.4 prior to 5.4.76849, and 5.5 prior to 5.5.90547 in the download_agent.php endpoint. An attacker can upload arbitrary PHP files to a temporary web-accessible directory, which are later executed through inclusion in backend code that loads files under attacker-controlled paths. |
| An unrestricted file upload vulnerability exists in Simple E-Document versions 3.0 to 3.1 that allows an unauthenticated attacker to bypass authentication by sending a specific cookie header (access=3) with HTTP requests. The application’s upload mechanism fails to restrict file types and does not validate or sanitize user-supplied input, allowing attackers to upload malicious .php scripts. Authentication can be bypassed entirely by supplying a specially crafted cookie (access=3), granting access to the upload functionality without valid credentials. If file uploads are enabled on the server, the attacker can upload a web shell and gain remote code execution with the privileges of the web server user, potentially leading to full system compromise. |
| The affected products allow unauthenticated access to Open Network Video Interface Forum (ONVIF) services, which may allow an attacker unauthorized access to camera configuration information. |
| SpaceX Starlink Dish devices with firmware 2024.12.04.mr46620 (e.g., on Mini1_prod2) allow administrative actions via unauthenticated LAN gRPC requests, aka MARMALADE 2. The cross-origin policy can be bypassed by omitting a Referer header. In some cases, an attacker's ability to read tilt, rotation, and elevation data via gRPC can make it easier to infer the geographical location of the dish. |
| E2 Facility Management Systems use a proprietary protocol that allows for unauthenticated file operations on any file in the file system. |
| djangorestframework-simplejwt version 5.3.1 and before is vulnerable to information disclosure. A user can access web application resources even after their account has been disabled due to missing user validation checks via the for_user method. |
| When configuring Arc (e.g. during the first setup), a local web interface is provided to ease the configuration process. Such web interface lacks authentication and may thus be abused by a local attacker or malware running on the machine itself.
A malicious local user or process, during a window of opportunity when the local web interface is active, may be able to extract sensitive information or change Arc's configuration. This could also lead to arbitrary code execution if a malicious update package is installed. |
| In WODESYS WD-R608U router (also known as WDR122B V2.0 and WDR28) due to lack of authentication in the configuration change module in the adm.cgi endpoint, the unauthenticated attacker can execute commands including backup creation, device restart and resetting the device to factory settings.
The vendor was notified early about this vulnerability, but didn't respond with the details of vulnerability or vulnerable version range. Only version WDR28081123OV1.01 was tested and confirmed as vulnerable, other versions were not tested and might also be vulnerable. |
| A vulnerability was identified in huggingface LeRobot up to 0.3.3. Affected by this vulnerability is an unknown functionality of the file lerobot/common/robot_devices/robots/lekiwi_remote.py of the component ZeroMQ Socket Handler. The manipulation leads to missing authentication. The attack can only be initiated within the local network. The vendor was contacted early about this disclosure but did not respond in any way. |
| The devices allow access to an unprotected endpoint that allows MPFS
file system binary image upload without authentication. The MPFS2 file
system module provides a light-weight read-only file system that can be
stored in external EEPROM, external serial flash, or internal flash
program memory. This file system serves as the basis for the HTTP2 web
server module, but is also used by the SNMP module and is available to
other applications that require basic read-only storage capabilities.
This can be exploited to overwrite the flash program memory that holds
the web server's main interfaces and execute arbitrary code. |
| FLIR Thermal Camera F/FC/PT/D Stream firmware version 8.0.0.64 contains an unauthenticated vulnerability that allows remote attackers to access live camera streams without credentials. Attackers can exploit the vulnerability to view unauthorized thermal camera video feeds across multiple camera series without requiring any authentication. |
| An unauthenticated command injection vulnerability exists in Serviio Media Server versions 1.4 through 1.8 on Windows, in the /rest/action API endpoint exposed by the console component (default port 23423). The checkStreamUrl method accepts a VIDEO parameter that is passed unsanitized to a call to cmd.exe, enabling arbitrary command execution under the privileges of the web server. No authentication is required to exploit this issue, as the REST API is exposed by default and lacks access controls. |
| A vulnerability allows unauthorized access to functionality inadequately constrained by ACLs. Attackers may exploit this to unauthenticated execute commands potentially leading to unauthorized data manipulation, access to privileged functions, or even the execution of arbitrary code. |
| The health module has insufficient restrictions on loading URLs, which may lead to some information leakage. |
| The MinigameCenter module has insufficient restrictions on loading URLs, which may lead to some information leakage. |
| An unauthenticated remote attacker may use the devices traffic capture without authentication to grab plaintext administrative credentials. |
| Tellion HN-2204AP routers contain an unauthenticated configuration disclosure vulnerability in the /cgi-bin/system_config_file management endpoint. The endpoint allows remote retrieval of a compressed configuration archive without requiring authentication or authorization. The exposed configuration may include administrative credentials, wireless keys, and other sensitive settings, enabling an unauthenticated attacker to obtain information that can facilitate further compromise of the device or network. |
| The Iskra iHUB and iHUB Lite smart metering gateway exposes its web management interface without requiring authentication, allowing unauthenticated users to access and modify critical device settings. |
| A security issue exists within the 5032 16pt Digital Configurable module’s web server. Intercepted session credentials can be used within a 3-minute timeout window, allowing unauthorized users to perform privileged actions. |