| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The paths "/cgi-bin/CliniNET.prd/utils/userlogstat.pl", "/cgi-bin/CliniNET.prd/utils/usrlogstat.pl", and "/cgi-bin/CliniNET.prd/utils/dblogstat.pl" expose data containing session IDs. |
| Quest KACE Systems Management Appliance (SMA) 13.0.x before 13.0.385, 13.1.x before 13.1.81, 13.2.x before 13.2.183, 14.0.x before 14.0.341 (Patch 5), and 14.1.x before 14.1.101 (Patch 4) allows unauthenticated users to replace system licenses through a web interface intended for license renewal. Attackers can exploit this to replace valid licenses with expired or trial licenses, causing denial of service. |
| The Amp’ed RF BT-AP 111 Bluetooth access point's HTTP admin interface does not have an authentication feature, allowing unauthorized access to anyone with network access. |
| A Missing Authentication for Critical Function vulnerability in the UniFi Connect EV Station Pro may allow a malicious actor with physical or adjacent access to perform an unauthorized factory reset.
Affected Products:
UniFi Connect EV Station Pro (Version 1.5.18 and earlier)
Mitigation:
Update UniFi Connect EV Station Pro to Version 1.5.27 or later |
| FLIR thermal traffic cameras contain an unauthenticated vulnerability that allows remote attackers to access live video streams without credentials. Attackers can directly retrieve video streams by accessing specific endpoints like /live.mjpeg, /snapshot.jpg, and RTSP streaming URLs without authentication. |
| A flaw was found in systems utilizing LUKS-encrypted disks with GRUB configured for TPM-based auto-decryption. When GRUB is set to automatically decrypt disks using keys stored in the TPM, it reads the decryption key into system memory. If an attacker with physical access can corrupt the underlying filesystem superblock, GRUB will fail to locate a valid filesystem and enter rescue mode. At this point, the disk is already decrypted, and the decryption key remains loaded in system memory. This scenario may allow an attacker with physical access to access the unencrypted data without any further authentication, thereby compromising data confidentiality. Furthermore, the ability to force this state through filesystem corruption also presents a data integrity concern. |
| An unauthenticated OS command injection vulnerability exists within Xdebug versions 2.5.5 and earlier, a PHP debugging extension developed by Derick Rethans. When remote debugging is enabled, Xdebug listens on port 9000 and accepts debugger protocol commands without authentication. An attacker can send a crafted eval command over this interface to execute arbitrary PHP code, which may invoke system-level functions such as system() or passthru(). This results in full compromise of the host under the privileges of the web server user. |
| By default, the Packet Power Monitoring and Control Web Interface do not
enforce authentication mechanisms. This vulnerability could allow
unauthorized users to access and manipulate monitoring and control
functions. |
| Missing Authentication for Critical Function vulnerability in the mobile monitoring feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric AnalytiX versions 10.97.2 and prior, Mitsubishi Electric MobileHMI versions 10.97.2 and prior, Mitsubishi Electric IoTWorX version 10.95, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions AnalytiX versions 10.97.2 and prior, Mitsubishi Electric Iconics Digital Solutions MobileHMI versions 10.97.2 and prior, and Mitsubishi Electric Iconics Digital Solutions IoTWorX version 10.95 allows a remote unauthenticated attacker to bypass proper authentication and log in to the system when all of the following conditions are met: (1) Active Directory is used in the security setting (2) "Automatic log in" option is enabled in the security setting (3) The IcoAnyGlass IIS Application Pool is running under an Active Directory Domain Account. (4) The IcoAnyGlass IIS Application Pool account is included in GENESIS64, ICONCIS Suite, and MC Works64 Security and has permission to log in. |
| A local privilege escalation vulnerability exists in lastore-daemon, the system package manager daemon used in Deepin Linux (developed by Wuhan Deepin Technology Co., Ltd.). In versions 0.9.53-1 (Deepin 15.5) and 0.9.66-1 (Deepin 15.7), the D-Bus configuration permits any user in the sudo group to invoke the InstallPackage method without password authentication. By default, the first user created on Deepin is in the sudo group. An attacker with shell access can craft a .deb package containing a malicious post-install script and use dbus-send to install it via lastore-daemon, resulting in arbitrary code execution as root. |
| Unauthenticated CROWN APIs allow access to critical functions. This leads to the accessibility of large parts of the web application without authentication. |
| Vulnerability in mojofywp WP Affiliate Disclosure wp-affiliate-disclosure.This issue affects WP Affiliate Disclosure: from n/a through 1.2.6. |
| A client-side remote code execution vulnerability exists in Hanwha Techwin Smart Security Manager (SSM) versions 1.32 and 1.4, due to improper restrictions on the PUT method exposed by the bundled Apache ActiveMQ instance (running on port 8161). An attacker can exploit this flaw through a Cross-Origin Resource Sharing (CORS) bypass combined with JavaScript-triggered file uploads to the web server, ultimately resulting in arbitrary code execution with SYSTEM privileges.
This vulnerability bypasses the server-side mitigations introduced in ZDI-15-156 and ZDI-16-481 by shifting the exploitation to the client-side.
This product is now referred to as Hanwha Wisenet SSM and it is unknown if current versions are affected. |
| A vulnerability exists in the NodeRestriction admission controller in Kubernetes clusters where node users can delete their corresponding node object by patching themselves with an OwnerReference to a cluster-scoped resource. If the OwnerReference resource does not exist or is subsequently deleted, the given node object will be deleted via garbage collection. |
| An unauthenticated remote attacker can obtain limited sensitive information and/or DoS the device due to missing authentication for critical function. |
| The Brightpick Internal Logic Control web interface is accessible
without requiring user authentication. An unauthorized user could
exploit this interface to manipulate robot control functions, including
initiating or halting runners, assigning jobs, clearing stations, and
deploying storage totes. |
| An unauthenticated remote attacker can run arbitrary commands on the affected devices with high privileges because the authentication for the Node_RED server is not configured by default. |
| Missing Authentication for Critical Function vulnerability in TUBITAK BILGEM Software Technologies Research Institute Liderahenk allows Remote Code Inclusion.This issue affects Liderahenk: from 3.0.0 to 3.3.1 before 3.5.0. |
| An unauthenticated remote attacker can gain access to the cloud API due to a lack of authentication for a critical function in the affected devices. Availability is not affected. |
| A vulnerability has been discovered in AC Smart II where passwords can be changed without authorization. This page contains a hidden form for resetting the administrator password. The attacker can manipulate the page using developer tools to display and use the form. This form allows you to change the administrator password without verifying login status or user permissions. |