| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An issue was discovered in Schneider Electric PowerLogic PM8ECC device 2.651 and older. Undocumented hard-coded credentials allow access to the device. |
| A Use of Hard-Coded Cryptographic Key issue was discovered in MRD-305-DIN versions older than 1.7.5.0, and MRD-315, MRD-355, MRD-455 versions older than 1.7.5.0. The device utilizes hard-coded private cryptographic keys that may allow an attacker to decrypt traffic from any other source. |
| ExaGrid appliances with firmware before 4.8 P26 have a default password of (1) inflection for the root shell account and (2) support for the support account in the web interface, which allows remote attackers to obtain administrative access via an SSH or HTTP session. |
| Trango ApexLynx 2.0, ApexOrion 2.0, GigaLynx 2.0, GigaOrion 2.0, and StrataLink 3.0 devices have a built-in, hidden root account, with a default password for which the MD5 hash value is public (but the cleartext value is perhaps not yet public). This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it. |
| The presence of a hardcoded account named 'core' in Fortinet FortiWLC allows attackers to gain unauthorized read/write access via a remote shell. |
| MEDHOST Connex contains hard-coded credentials that are used for customer database access. An attacker with knowledge of the hard-coded credentials and the ability to communicate directly with the database may be able to obtain or modify sensitive patient and financial information. Connex utilizes an IBM i DB2 user account for database access. The account name is HMSCXPDN. Its password is hard-coded in multiple places in the application. Customers do not have the option to change this password. The account has elevated DB2 roles, and can access all objects or database tables on the customer DB2 database. This account can access data through ODBC, FTP, and TELNET. Customers without Connex installed are still vulnerable because the MEDHOST setup program creates this account. |
| MEDHOST Document Management System contains hard-coded credentials that are used for customer database access. An attacker with knowledge of the hard-coded credentials and the ability to communicate directly with the database may be able to obtain or modify sensitive patient and financial information. PostgreSQL is used as the Document Management System database. The account name is dms. The password is hard-coded throughout the application, and is the same across all installations. Customers do not have the option to change passwords. The dms account for PostgreSQL has access to the database schema for Document Management System. |
| An issue was discovered in heinekingmedia StashCat through 1.7.5 for Android. The keystore is locked with a hard-coded password. Therefore, everyone with access to the keystore can read the content out, for example the private key of the user. |
| Foscam networked devices use the same hardcoded SSL private key across different customers' installations, which allows remote attackers to defeat cryptographic protection mechanisms by leveraging knowledge of this key from another installation. |
| A hard-coded password issue was discovered in Becton, Dickinson and Company (BD) PerformA, Version 2.0.14.0 and prior versions, and KLA Journal Service, Version 1.0.51 and prior versions. They use hard-coded passwords to access the BD Kiestra Database, which could be leveraged to compromise the confidentiality of limited PHI/PII information stored in the BD Kiestra Database. |
| A vulnerability in motherboard console ports of line cards for Cisco ASR 1000 Series Aggregation Services Routers and Cisco cBR-8 Converged Broadband Routers could allow an unauthenticated, physical attacker to access an affected device's operating system. The vulnerability exists because an engineering console port is available on the motherboard of the affected line cards. An attacker could exploit this vulnerability by physically connecting to the console port on the line card. A successful exploit could allow the attacker to gain full access to the affected device's operating system. This vulnerability affects only Cisco ASR 1000 Series Routers that have removable line cards and Cisco cBR-8 Converged Broadband Routers, if they are running certain Cisco IOS XE 3.16 through 16.5 releases. Cisco Bug IDs: CSCvc65866, CSCve77132. |
| An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Users do not have any option to change their own passwords. |
| On BE126 WIFI repeater 1.0 devices, an attacker can log into telnet (which is open by default) with default credentials as root (username:"root" password:"root") and can: 1. Read the entire file system; 2. Write to the file system; or 3. Execute any code that attacker desires (malicious or not). |
| An issue was discovered in Lynxspring JENEsys BAS Bridge versions 1.1.8 and older. The application uses a hard-coded username with no password allowing an attacker into the system without authentication. |
| A hard-coded credentials issue was discovered on Mimosa Client Radios before 2.2.3, Mimosa Backhaul Radios before 2.2.3, and Mimosa Access Points before 2.2.3. These devices run Mosquitto, a lightweight message broker, to send information between devices. By using the vendor's hard-coded credentials to connect to the broker on any device (whether it be an AP, Client, or Backhaul model), an attacker can view all the messages being sent between the devices. If an attacker connects to an AP, the AP will leak information about any clients connected to it, including the serial numbers, which can be used to remotely factory reset the clients via a page in their web interface. |
| A hard-coded account named 'upgrade' in Fortinet FortiWLM 8.3.0 and lower versions allows a remote attacker to log-in and execute commands with 'upgrade' account privileges. |
| CloudForms Management Engine before 5.8 includes a default SSL/TLS certificate. |
| Wireless IP Camera (P2P) WIFICAM devices have a backdoor root account that can be accessed with TELNET. |
| WN-G300R3 firmware version 1.0.2 and earlier uses hardcoded credentials which may allow an attacker that can access the device to execute arbitrary code on the device. |
| An issue was discovered in Siemens SICAM PAS before 8.00. A factory account with hard-coded passwords is present in the SICAM PAS installations. Attackers might gain privileged access to the database over Port 2638/TCP. |