| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A vulnerability, which was classified as critical, has been found in IROAD Dash Cam X5 and Dash Cam X6 up to 20250308. Affected by this issue is some unknown functionality of the component API Endpoint. The manipulation leads to missing authentication. The attack may be launched remotely. The vendor was contacted early about this disclosure but did not respond in any way. |
| E2 Facility Management Systems use a proprietary protocol that allows for unauthenticated file operations on any file in the file system. |
| A vulnerability was identified in huggingface LeRobot up to 0.3.3. Affected by this vulnerability is an unknown functionality of the file lerobot/common/robot_devices/robots/lekiwi_remote.py of the component ZeroMQ Socket Handler. The manipulation leads to missing authentication. The attack can only be initiated within the local network. The vendor was contacted early about this disclosure but did not respond in any way. |
| A remote unauthenticated attacker may be able to bypass authentication
by utilizing a specific API route to execute arbitrary OS commands. |
| COMMAX Smart Home System is a smart IoT home solution that allows an unauthenticated attacker to disclose RTSP credentials in plain-text by exploiting the /overview.asp endpoint. Attackers can access sensitive information, including login credentials and DVR settings, by submitting a GET request to this endpoint. |
| Missing Authentication, Files or Directories Accessible to External Parties, Use of Hard-coded Credentials vulnerability in Talya Informatics Elektraweb allows Authentication Bypass.This issue affects Elektraweb: before v17.0.68. |
| A vulnerability was found in eGauge EG3000 Energy Monitor 3.6.3. It has been classified as problematic. This affects an unknown part of the component Setting Handler. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Missing authentication for critical function vulnerability exists in Wi-Fi AP UNIT 'AC-WPS-11ac series'. If exploited, a remote unauthenticated attacker may obtain the product configuration information including authentication information. |
| In the Airoha Bluetooth audio SDK, there is a possible unauthorized access to the RACE protocol. This could lead to remote escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. |
| The health module has insufficient restrictions on loading URLs, which may lead to some information leakage. |
| The "serverConfig" endpoint, which returns the module configuration including credentials, is accessible without authentication. |
| An unauthenticated remote attacker can access a URL which causes the device to reboot. |
| The MinigameCenter module has insufficient restrictions on loading URLs, which may lead to some information leakage. |
| Missing Authentication for Critical Function, Missing Authorization vulnerability in Yordam Information Technology Mobile Library Application allows Retrieve Embedded Sensitive Data.This issue affects Mobile Library Application: before 5.0. |
| The endpoint hosts a script that allows an unauthorized remote attacker to put the system in a fail-safe state over the network due to missing authentication. |
| A remote code execution vulnerability exists in HybridAuth versions 2.0.9 through 2.2.2 due to insecure use of the install.php installation script. The script remains accessible after deployment and fails to sanitize input before writing to the application’s config.php file. An unauthenticated attacker can inject arbitrary PHP code into config.php, which is later executed when the file is loaded. This allows attackers to achieve remote code execution on the server. Exploitation of this issue will overwrite the existing configuration, rendering the application non-functional. |
| Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series CPU module allows a remote unauthenticated attacker to read or write the device values of the product and stop the operation of the programs, since MODBUS/TCP in the products does not have authentication features. |
| Certain Anpviz products allow unauthenticated users to modify or disable camera related settings such as microphone volume, speaker volume, LED lighting, NTP, motion detection, etc. This affects IPC-D250, IPC-D260, IPC-B850, IPC-D850, IPC-D350, IPC-D3150, IPC-D4250, IPC-D380, IPC-D880, IPC-D280, IPC-D3180, MC800N, YM500L, YM800N_N2, YMF50B, YM800SV2, YM500L8, and YM200E10 firmware v3.2.2.2 and lower and possibly more vendors/models of IP camera. |
| The wallet has an authentication bypass vulnerability that allows access to specific pages. |
| A malicious actor can access camera configuration information, including account credentials, without authenticating when accessing a vulnerable URL. |