Search Results (362 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-32445 1 Argoproj 1 Argo Events 2026-04-15 10 Critical
Argo Events is an event-driven workflow automation framework for Kubernetes. A user with permission to create/modify EventSource and Sensor custom resources can gain privileged access to the host system and cluster, even without having direct administrative privileges. The EventSource and Sensor CRs allow the corresponding orchestrated pod to be customized with spec.template and spec.template.container (with type k8s.io/api/core/v1.Container), thus, any specification under container such as command, args, securityContext , volumeMount can be specified, and applied to the EventSource or Sensor pod. With these, a user would be able to gain privileged access to the cluster host, if he/she specified the EventSource/Sensor CR with some particular properties under template. This vulnerability is fixed in v1.9.6.
CVE-2025-6894 1 Moxa 7 Edf-g1002-bp, Edr-8010, Edr-g9010 and 4 more 2026-04-15 N/A
An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and routers. A flaw in the API authorization logic of the affected device allows an authenticated, low-privileged user to execute the administrative `ping` function, which is restricted to higher-privileged roles. This vulnerability enables the user to perform internal network reconnaissance, potentially discovering internal hosts or services that would otherwise be inaccessible. Repeated exploitation could lead to minor resource consumption. While the overall impact is limited, it may result in some loss of confidentiality and availability on the affected device. There is no impact on the integrity of the device, and the vulnerability does not affect any subsequent systems.
CVE-2025-13911 2 Inductiveautomation, Microsoft 2 Ignition, Windows 2026-04-15 6.4 Medium
The vulnerability affects Ignition SCADA applications where Python scripting is utilized for automation purposes. The vulnerability arises from the absence of proper security controls that restrict which Python libraries can be imported and executed within the scripting environment. The core issue lies in the Ignition service account having system permissions beyond what an Ignition privileged user requires. When an authenticated administrator uploads a malicious project file containing Python scripts with bind shell capabilities, the application executes these scripts with the same privileges as the Ignition Gateway process, which typically runs with SYSTEM-level permissions on Windows. Alternative code execution patterns could lead to similar results.
CVE-2024-43652 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVE-2024-12673 1 Lenovo 1 Vantage 2026-04-15 7.8 High
An improper privilege vulnerability was reported in a BIOS customization feature of Lenovo Vantage on SMB notebook devices which could allow a local attacker to elevate privileges on the system. This vulnerability only affects Vantage installed on these devices: * Lenovo V Series (Gen 5) * ThinkBook 14 (Gen 6, 7) * ThinkBook 16 (Gen 6, 7) * ThinkPad E Series (Gen 1)
CVE-2025-9055 3 Axis, Axis Communications Ab, Linux 3 Axis Os, Axis Os, Linux 2026-04-15 6.4 Medium
The VAPIX Edge storage API that allowed a privilege escalation, enabling a VAPIX administrator-privileged user to gain Linux Root privileges. This flaw can only be exploited after authenticating with an administrator-privileged service account.
CVE-2025-32802 1 Redhat 1 Enterprise Linux 2026-04-15 6.1 Medium
Kea configuration and API directives can be used to overwrite arbitrary files, subject to permissions granted to Kea. Many common configurations run Kea as root, leave the API entry points unsecured by default, and/or place the control sockets in insecure paths. This issue affects Kea versions 2.4.0 through 2.4.1, 2.6.0 through 2.6.2, and 2.7.0 through 2.7.8.
CVE-2024-43654 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43650 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects  firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y).
CVE-2025-23395 2026-04-15 7.8 High
Screen 5.0.0 when it runs with setuid-root privileges does not drop privileges while operating on a user supplied path. This allows unprivileged users to create files in arbitrary locations with `root` ownership, the invoking user's (real) group ownership and file mode 0644. All data written to the Screen PTY will be logged into this file, allowing to escalate to root privileges
CVE-2024-11075 1 Sick Ag 1 Incoming Goods Suite 2026-04-15 8.8 High
A vulnerability in the Incoming Goods Suite allows a user with unprivileged access to the underlying system (e.g. local or via SSH) a privilege escalation to the administrative level due to the usage of component vendor Docker images running with root permissions. Exploiting this misconfiguration leads to the fact that an attacker can gain administrative control. over the whole system.
CVE-2025-50505 1 Clash-verge 1 Clash-verge 2026-04-15 7.8 High
Clash Verge Rev thru 2.2.3 (fixed in 2.3.0) forces the installation of system services(clash-verge-service) by default and exposes key functions through the unauthorized HTTP API `/start_clash`, allowing local users to submit arbitrary bin_path parameters and pass them directly to the service process for execution, resulting in local privilege escalation.
CVE-2025-50753 1 Mitrastar 1 Gpt-2741gnac-n2 2026-04-15 8.4 High
Mitrastar GPT-2741GNAC-N2 devices are provided with access through ssh into a restricted default shell.The command "deviceinfo show file" is supposed to be used from restricted shell to show files and directories. By providing " /bin/sh" (quotes included) to the argument of this command will drop a root shell.
CVE-2025-8907 2026-04-15 7 High
A vulnerability was found in H3C M2 NAS V100R006. Affected by this vulnerability is an unknown functionality of the component Webserver Configuration. The manipulation leads to execution with unnecessary privileges. An attack has to be approached locally. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The vendor explains: "[T]he device only has configuration files and does not actually have boa functionality. It is impossible to access or upload files anonymously to the device through boa services". This vulnerability only affects products that are no longer supported by the maintainer.
CVE-2025-24331 2026-04-15 6.4 Medium
The Single RAN baseband OAM service is intended to run as an unprivileged service. However, it initially starts with root privileges and assigns certain capabilities before dropping to an unprivileged level. The capabilities retained from the root period are considered extensive after the privilege drop and, in theory, could potentially allow actions beyond the intended scope of the OAM service. These actions could include gaining root privileges, accessing root-owned files, modifying them as the file owner, and then returning them to root ownership. This issue has been corrected starting from release 24R1-SR 0.2 MP and later. Beginning with release 24R1-SR 0.2 MP, the OAM service software capabilities are restricted to the minimum necessary.
CVE-2025-22367 2026-04-15 N/A
The authenticated time setting capability of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS command are improperly neutralized when certain fields are passed to the underlying OS.
CVE-2024-50590 1 Hasomed 1 Elefant 2026-04-15 7.8 High
Attackers with local access to the medical office computer can escalate their Windows user privileges to "NT AUTHORITY\SYSTEM" by overwriting one of two Elefant service binaries with weak permissions. The default installation directory of Elefant is "C:\Elefant1" which is writable for all users. In addition, the Elefant installer registers two Firebird database services which are running as “NT AUTHORITY\SYSTEM”.  Path: C:\Elefant1\Firebird_2\bin\fbserver.exe Path: C:\Elefant1\Firebird_2\bin\fbguard.exe Both service binaries are user writable. This means that a local attacker can rename one of the service binaries, replace the service executable with a new executable, and then restart the system. Once the system has rebooted, the new service binary is executed as "NT AUTHORITY\SYSTEM".
CVE-2025-37128 2 Arubanetworks, Hp 2 Edgeconnect Enterprise, Arubaos 2026-04-15 6.8 Medium
A vulnerability in the web API of HPE Aruba Networking EdgeConnect SD-WAN Gateways could allow an authenticated remote attacker to terminate arbitrary running processes. Successful exploitation could allow an attacker to disrupt system operations, potentially resulting in an unstable system state.
CVE-2024-52799 1 Argoproj 1 Argo-helm 2026-04-15 8.3 High
Argo Workflows Chart is used to set up argo and its needed dependencies through one command. Prior to 0.44.0, the workflow-role has excessive privileges, the worst being create pods/exec, which will allow kubectl exec into any Pod in the same namespace, i.e. arbitrary code execution within those Pods. If a user can be made to run a malicious template, their whole namespace can be compromised. This affects versions of the argo-workflows Chart that use appVersion: 3.4 and above, which no longer need these permissions for the only available Executor, Emissary. It could also affect users below 3.4 depending on their choice of Executor in those versions. This only affects the Helm Chart and not the upstream manifests. This vulnerability is fixed in 0.44.0.
CVE-2024-8767 1 Acronis 3 Backup Extension For Plesk, Backup Plugin For Cpanel \& Whm, Backup Plugin For Directadmin 2026-04-15 N/A
Sensitive data disclosure and manipulation due to unnecessary privileges assignment. The following products are affected: Acronis Backup plugin for cPanel & WHM (Linux) before build 619, Acronis Backup extension for Plesk (Linux) before build 555, Acronis Backup plugin for DirectAdmin (Linux) before build 147.