| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An unauthenticated remote attacker can access a URL which causes the device to reboot. |
| Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation G-50 all versions, G-50-W all versions, G-50A all versions, GB-50 all versions, GB-50A all versions, GB-24A all versions, G-150AD all versions, AG-150A-A all versions, AG-150A-J all versions, GB-50AD all versions, GB-50ADA-A all versions, GB-50ADA-J all versions, EB-50GU-A all versions, EB-50GU-J all versions, AE-200J all versions, AE-200A all versions, AE-200E all versions, AE-50J all versions, AE-50A all versions, AE-50E all versions, EW-50J all versions, EW-50A all versions, EW-50E all versions, TE-200A all versions, TE-50A all versions, TW-50A all versions, and CMS-RMD-J all versions allows a remote unauthenticated attacker to bypass authentication and then control the air conditioning systems illegally, or disclose information in them by exploiting this vulnerability. In addition, the attacker may tamper with firmware for them using the disclosed information. |
| An issue was discovered on Marbella KR8s Dashcam FF 2.0.8 devices. Via port 7777 without any need to pair or press a physical button, a remote attacker can disable recording, delete recordings, or even disable battery protection to cause a flat battery to essentially disable the car from being used. During the process of changing these settings, there are no indications or sounds on the dashcam to alert the dashcam owner that someone else is making those changes. |
| OMNTEC Proteus Tank Monitoring OEL8000III Series
could allow an attacker to perform administrative actions without proper authentication. |
| Missing authentication for critical function vulnerability exists in Wi-Fi AP UNIT 'AC-WPS-11ac series'. If exploited, a remote unauthenticated attacker may obtain the product configuration information including authentication information. |
| Unified Remote 3.9.0.2463 contains a remote code execution vulnerability that allows attackers to send crafted network packets to execute arbitrary commands. Attackers can exploit the service by connecting to port 9512 and sending specially crafted packets to open a command prompt and download and execute malicious payloads. |
| An unauthenticated adjacent attacker could potentially disrupt operations by switching between multiple configuration presets via Modbus (RS485). |
| A vulnerability in the handling of verify_mode = CERT_REQUIRED in the wolfssl Python package (wolfssl-py) causes client certificate requirements to not be fully enforced.
Because the WOLFSSL_VERIFY_FAIL_IF_NO_PEER_CERT flag was not included, the behavior effectively matched CERT_OPTIONAL: a peer certificate was verified if presented, but connections were incorrectly authenticated when no client certificate was provided.
This results in improper authentication, allowing attackers to bypass mutual TLS (mTLS) client authentication by omitting a client certificate during the TLS handshake.
The issue affects versions up to and including 5.8.2. |
| A remote unauthenticated attacker may be able to bypass authentication
by utilizing a specific API route to execute arbitrary OS commands. |
| The ISOinsight from Netvision has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to access certain system functions. These functions include viewing the administrator list, viewing and editing IP settings, and uploading files. |
| DBPower C300 HD Camera contains a configuration disclosure vulnerability that allows unauthenticated attackers to retrieve sensitive credentials through an unprotected configuration backup endpoint. Attackers can download the configuration file and extract hardcoded username and password by accessing the /tmpfs/config_backup.bin resource. |
| General Bytes Crypto Application Server (CAS) beginning with version 20201208 prior to 20220531.38 (backport) and 20220725.22 (mainline) contains an authentication bypass in the admin web interface. An unauthenticated attacker could invoke the same URL used by the product's default-installation / first-admin creation page and create a new administrative account remotely. By gaining admin privileges, the attacker can change the ATM configuration resulting in redirected funds. Public vendor advisories and multiple independent writeups describe the vulnerability as a call to the page used for initial/default installation / first administration user creation; General Bytes has not publicly published the exact endpoint/parameter name. The issue was actively exploited in the wild against cloud-hosted and standalone CAS deployments (scanning exposed CAS instances on ports 7777/443), and publicly acknowledged by the General Bytes in September 2022. |
| A local privilege escalation vulnerability exists in Agnitum Outpost Internet Security 8.1 that allows an unprivileged user to execute arbitrary code with SYSTEM privileges. The flaw resides in the acs.exe component, which exposes a named pipe that accepts unauthenticated commands. By exploiting a directory traversal weakness in the pipe protocol, an attacker can instruct the service to load a malicious DLL from a user-controlled location. The DLL is then executed in the context of the privileged service. |
| A device takeover vulnerability exists in the Rockwell Automation Power Monitor 1000. This vulnerability allows configuration of a new Policyholder user without any authentication via API. Policyholder user is the most privileged user that can perform edit operations, creating admin users and performing factory reset. |
| An unauthenticated attacker can reset the board and stop transmitter
operations by sending a specially-crafted GET request to the command.cgi
gateway, resulting in a denial-of-service scenario. |
| TEM Opera Plus FM Family Transmitter allows access to an unprotected endpoint that allows MPFS File System binary image upload without authentication. This file system serves as the basis for the HTTP2 web server module but is also used by the SNMP module and is available to other applications that require basic read-only storage capabilities. This can be exploited to overwrite the flash program memory that holds the web server's main interfaces and execute arbitrary code. |
| An issue was discovered in Atos Eviden iCare 2.7.1 through 2.7.11. The application exposes a web interface locally. In the worst-case scenario, if the application is remotely accessible, it allows an attacker to execute arbitrary commands with system privilege on the endpoint hosting the application, without any authentication. |
| A Missing Authentication for Critical Function vulnerability in the GRUB configuration used B&R APROL <4.4-01 may allow an unauthenticated physical attacker to alter the boot configuration of the operating system. |
| CWE-306: Missing Authentication for Critical Function vulnerability exists that could
cause exposure of private data when an already generated “logcaptures” archive is accessed
directly by HTTPS. |
| Instantel Micromate lacks authentication on a configuration port which could allow an attacker to execute commands if connected. |