| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| In the "NQ Contacts Backup & Restore" application 1.1 for Android, RC4 encryption is used to secure the user password locally stored in shared preferences. Because there is a static RC4 key, an attacker can gain access to user credentials more easily by leveraging access to the preferences XML file. |
| In the "NQ Contacts Backup & Restore" application 1.1 for Android, DES encryption with a static key is used to secure transmitted contact data. This makes it easier for remote attackers to obtain cleartext information by sniffing the network. |
| An Inadequate Encryption Strength issue was discovered in Schneider Electric Wonderware InTouch Access Anywhere, version 11.5.2 and prior. The software will connect via Transport Layer Security without verifying the peer's SSL certificate properly. |
| VMware vSphere Data Protection (VDP) 6.1.x, 6.0.x, 5.8.x, and 5.5.x locally stores vCenter Server credentials using reversible encryption. This issue may allow plaintext credentials to be obtained. |
| On the TP-Link TL-SG108E 1.0, admin network communications are RC4 encoded, even though RC4 is deprecated. This affects the 1.1.2 Build 20141017 Rel.50749 firmware. |
| Sonatype Nexus Repository Manager through 2.14.5 has weak password encryption with a hardcoded CMMDwoV value in the LDAP integration feature. |
| OceanStor 5800 V3 with software V300R002C00 and V300R002C10, OceanStor 6900 V3 V300R001C00 has an information leakage vulnerability. Products use TLS1.0 to encrypt. Attackers can exploit TLS1.0's vulnerabilities to decrypt data to obtain sensitive information. |
| Wi-Fi Protected Access (WPA and WPA2) that supports IEEE 802.11w allows reinstallation of the Integrity Group Temporal Key (IGTK) during the four-way handshake, allowing an attacker within radio range to spoof frames from access points to clients. |
| Sympa before 6.2.62 relies on a cookie parameter for certain security objectives, but does not ensure that this parameter exists and has an unpredictable value. Specifically, the cookie parameter is both a salt for stored passwords and an XSS protection mechanism. |
| The DeskLock tool provided with FactoryTalk View SE uses a weak encryption algorithm that may allow a local, authenticated attacker to decipher user credentials, including the Windows user or Windows DeskLock passwords. If the compromised user has an administrative account, an attacker could gain full access to the user’s operating system and certain components of FactoryTalk View SE. |
| In specific scenarios, on Windows the operator credentials may be encrypted in a manner that is not completely machine-dependent.
|
| Ovarro TBox TWinSoft uses the custom hardcoded user “TWinSoft” with a hardcoded key. |
| Fresenius Kabi Vigilant Software Suite (Mastermed Dashboard) version 2.0.1.3 issues authentication tokens to authenticated users that are signed with a symmetric encryption key. An attacker in possession of the key can issue valid JWTs and impersonate arbitrary users. |
| The use of a broken or risky cryptographic algorithm in Philips Vue PACS versions 12.2.x.x and prior is an unnecessary risk that may result in the exposure of sensitive information. |
| The SSL/TLS configuration of Fresenius Kabi Agilia Link + version 3.0 has serious deficiencies that may allow an attacker to compromise SSL/TLS sessions in different ways. An attacker may be able to eavesdrop on transferred data, manipulate data allegedly secured by SSL/TLS, and impersonate an entity to gain access to sensitive information. |
| Fresenius Kabi Agilia Link + version 3.0 does not enforce transport layer encryption. Therefore, transmitted data may be sent in cleartext. Transport layer encryption is offered on Port TCP/443, but the affected service does not perform an automated redirect from the unencrypted service on Port TCP/80 to the encrypted service. |
| The affected product has a hardcoded private key available inside the project folder, which may allow an attacker to achieve Web Server login and perform further actions. |
| MMP: All versions prior to v1.0.3, PTP C-series: Device versions prior to v2.8.6.1, and PTMP C-series and A5x: Device versions prior to v2.5.4.1 uses the MD5 algorithm to hash the passwords before storing them but does not salt the hash. As a result, attackers may be able to crack the hashed passwords. |
| Inadequate encryption may allow the passwords for Emerson OpenEnterprise versions through 3.3.4 user accounts to be obtained. |
| Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm (TEA) on an entered or saved password. A remote, unauthenticated attacker could pass their own encrypted password to the ISaGRAF 5 Runtime, which may result in information disclosure on the device. |