| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Improper Handling of Length Parameter Inconsistency vulnerability in web server function on Mitsubishi Electric Corporation MELSEC iQ-F Series CPU module allows a remote unauthenticated attacker to delay the processing of the web server function and prevent legitimate users from utilizing the web server function, by sending a specially crafted HTTP request. |
| On-Chip Debug and Test Interface With Improper Access Control and Improper Protection against Electromagnetic Fault Injection (EM-FI) in Nordic Semiconductor nRF52810 allow attacker to perform EM Fault Injection and bypass APPROTECT at runtime, requiring the least amount of modification to the hardware system possible. |
| A vulnerability has been identified in APOGEE PXC Series (BACnet) (All versions), APOGEE PXC Series (P2 Ethernet) (All versions), TALON TC Series (BACnet) (All versions). Affected devices contain a weak encryption mechanism based on a hard-coded key.
This could allow an attacker to guess or decrypt the password from the cyphertext. |
| Improper input validation in firmware for some Intel(R) Server M20NTP Family UEFI may allow a privileged user to potentially enable escalation of privilege via local access. |
| A vulnerability had been discovered in WinNMP 19.02 consisting of an XSS attack via index page in from, subject, text and hash parameters. This vulnerability could allow a remote user to send a specially crafted query to an authenticated user and steal their session details. |
| A potential null pointer dereference vulnerability was reported in the Lenovo Power Management Driver that could allow a local authenticated user to cause a Windows blue screen error. |
| In the Linux kernel, the following vulnerability has been resolved:
hwmon: (cgbc-hwmon) Add missing NULL check after devm_kzalloc()
The driver allocates memory for sensor data using devm_kzalloc(), but
did not check if the allocation succeeded. In case of memory allocation
failure, dereferencing the NULL pointer would lead to a kernel crash.
Add a NULL pointer check and return -ENOMEM to handle allocation failure
properly. |
| A code injection vulnerability can allow a low-privileged user to overwrite files on that VSPC server, which can lead to remote code execution on VSPC server. |
| "SwitchBot" App for iOS/Android contains an insertion of sensitive information into log file vulnerability in versions V6.24 through V9.12. If this vulnerability is exploited, sensitive user information may be exposed to an attacker who has access to the application logs. |
| An unauthenticated remote attacker can change the admin password in a moneo appliance due to weak password recovery mechanism.
|
| The WP Hotel Booking WordPress plugin before 2.2.3 lacks proper server-side validation for review ratings, allowing an attacker to manipulate the rating value (e.g., sending negative or out-of-range values) by intercepting and modifying requests. |
| On affected platforms running Arista EOS, certain serial console input might result in an unexpected reload of the device.153 |
| ASKEY 5G NR Small Cell fails to properly filter user input for certain functionality, allowing remote attackers with administrator privilege to execute arbitrary system commands on the remote server. |
| Press, a Frappe custom app that runs Frappe Cloud, manages infrastructure, subscription, marketplace, and software-as-a-service (SaaS). Users can circumvent 2FA login for users due to a lack of server side validation for the same. This vulnerability is fixed in commit ddb439f8eb1816010f2ef653a908648b71f9bba8. |
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7KE85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SA87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SS85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7ST85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7ST85 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) V9.8x (All versions < V9.83), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VK87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions >= V8.80 < V9.90), SIPROTEC 5 Communication Module ETH-BD-2FO V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BD-2FO V9.8 (All versions < V9.83), SIPROTEC 5 Compact 7SX800 (CP050) (All versions >= V9.50 < V9.90). Affected devices do not properly validate SNMP GET requests. This could allow an unauthenticated, remote attacker to retrieve sensitive information of the affected devices with SNMPv2 GET requests using default credentials. |
| Path Traversal vulnerability in API Endpoint in Mobile Industrial Robots (MiR) Software Versions prior to 3.0.0 on MiR Robots allows authenticated users to extract files from the robot file system via a crafted API request. |
| A vulnerability in the firewall component of HPE Aruba Networking CX 10000 Series Switches exists. It could allow an unauthenticated adjacent attacker to conduct a packet forwarding attack against the ICMP and UDP protocol. For this attack to be successful an attacker requires a switch configuration that allows packets routing (at layer 3). Configurations that do not allow network traffic routing are not impacted. Successful exploitation could allow an attacker to bypass security policies, potentially leading to unauthorized data exposure. |
| An unquoted service path in Kingosoft Technology Ltd Kingo ROOT v1.5.8.3353 allows attackers to escalate privileges via placing a crafted executable file into a parent folder. |
| MiR software versions prior to version 3.0.0 are affected by a command injection vulnerability. A malicious
HTTP request crafted by an authenticated user could allow the execution of arbitrary commands on the
underlying operating system. |
| A vulnerability was found in Guangdong Baolun Electronics IP Network Broadcasting Service Platform 2.0. It has been classified as critical. Affected is an unknown function of the file /api/v2/maps. The manipulation of the argument orderColumn leads to sql injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-268692. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |