Search Results (354865 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-55346 1 Flowiseai 1 Flowise 2026-04-15 9.8 Critical
User-controlled input flows to an unsafe implementation of a dynamic Function constructor, allowing network attackers to run arbitrary unsandboxed JS code in the context of the host, by sending a simple POST request.
CVE-2024-54092 2026-04-15 9.8 Critical
A vulnerability has been identified in Industrial Edge Device Kit - arm64 V1.17 (All versions), Industrial Edge Device Kit - arm64 V1.18 (All versions), Industrial Edge Device Kit - arm64 V1.19 (All versions), Industrial Edge Device Kit - arm64 V1.20 (All versions < V1.20.2-1), Industrial Edge Device Kit - arm64 V1.21 (All versions < V1.21.1-1), Industrial Edge Device Kit - x86-64 V1.17 (All versions), Industrial Edge Device Kit - x86-64 V1.18 (All versions), Industrial Edge Device Kit - x86-64 V1.19 (All versions), Industrial Edge Device Kit - x86-64 V1.20 (All versions < V1.20.2-1), Industrial Edge Device Kit - x86-64 V1.21 (All versions < V1.21.1-1), Industrial Edge Own Device (IEOD) (All versions < V1.21.1-1-a), Industrial Edge Virtual Device (All versions < V1.21.1-1-a), SCALANCE LPE9413 (6GK5998-3GS01-2AC2) (All versions < V2.1), SIMATIC IPC BX-39A Industrial Edge Device (All versions < V3.0), SIMATIC IPC BX-59A Industrial Edge Device (All versions < V3.0), SIMATIC IPC127E Industrial Edge Device (All versions < V3.0), SIMATIC IPC227E Industrial Edge Device (All versions < V3.0), SIMATIC IPC427E Industrial Edge Device (All versions < V3.0), SIMATIC IPC847E Industrial Edge Device (All versions < V3.0). Affected devices do not properly enforce user authentication on specific API endpoints when identity federation is used. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that identity federation is currently or has previously been used and the attacker has learned the identity of a legitimate user.
CVE-2025-1207 2026-04-15 3.1 Low
A vulnerability was found in phjounin TFTPD64 4.64. It has been declared as problematic. This vulnerability affects unknown code of the component DNS Handler. The manipulation leads to denial of service. The attack needs to be done within the local network. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used.
CVE-2025-34082 1 Igel 1 Igel Os 2026-04-15 N/A
A command injection vulnerability exists in IGEL OS versions prior to 11.04.270 within the Secure Terminal and Secure Shadow services. The flaw arises due to improper input sanitization in the handling of specially crafted PROXYCMD commands on TCP ports 30022 and 5900. An unauthenticated attacker with network access to a vulnerable device can inject arbitrary commands, leading to remote code execution with elevated privileges. NOTE: IGEL OS v10.x has reached end-of-life (EOL) status.
CVE-2025-34061 2026-04-15 N/A
A backdoor in PHPStudy versions 2016 through 2018 allows unauthenticated remote attackers to execute arbitrary PHP code on affected installations. The backdoor listens for base64-encoded PHP payloads in the Accept-Charset HTTP header of incoming requests, decodes and executes the payload without proper validation. This leads to remote code execution as the web server user, compromising the affected system.
CVE-2024-54090 2026-04-15 5.9 Medium
A vulnerability has been identified in APOGEE PXC Series (BACnet) (All versions), APOGEE PXC Series (P2 Ethernet) (All versions), TALON TC Series (BACnet) (All versions). Affected devices contain an out-of-bounds read in the memory dump function. This could allow an attacker with Medium (MED) or higher privileges to cause the device to enter an insecure cold start state.
CVE-2025-5514 1 Mitsubishi Electric 1 Melsec Iq-f Series 2026-04-15 5.3 Medium
Improper Handling of Length Parameter Inconsistency vulnerability in web server function on Mitsubishi Electric Corporation MELSEC iQ-F Series CPU module allows a remote unauthenticated attacker to delay the processing of the web server function and prevent legitimate users from utilizing the web server function, by sending a specially crafted HTTP request.
CVE-2024-54089 2026-04-15 7.5 High
A vulnerability has been identified in APOGEE PXC Series (BACnet) (All versions), APOGEE PXC Series (P2 Ethernet) (All versions), TALON TC Series (BACnet) (All versions). Affected devices contain a weak encryption mechanism based on a hard-coded key. This could allow an attacker to guess or decrypt the password from the cyphertext.
CVE-2024-39811 1 Intel 1 M20ntp Firmware 2026-04-15 6.3 Medium
Improper input validation in firmware for some Intel(R) Server M20NTP Family UEFI may allow a privileged user to potentially enable escalation of privilege via local access.
CVE-2024-5406 2026-04-15 6.3 Medium
A vulnerability had been discovered in WinNMP 19.02 consisting of an XSS attack via index page in from, subject, text and hash parameters. This vulnerability could allow a remote user to send a specially crafted query to an authenticated user and steal their session details.
CVE-2025-9548 2 Lenovo, Microsoft 2 Power Management Driver, Windows 2026-04-15 5.5 Medium
A potential null pointer dereference vulnerability was reported in the Lenovo Power Management Driver that could allow a local authenticated user to cause a Windows blue screen error.
CVE-2025-40224 1 Linux 1 Linux Kernel 2026-04-15 5.5 Medium
In the Linux kernel, the following vulnerability has been resolved: hwmon: (cgbc-hwmon) Add missing NULL check after devm_kzalloc() The driver allocates memory for sensor data using devm_kzalloc(), but did not check if the allocation succeeded. In case of memory allocation failure, dereferencing the NULL pointer would lead to a kernel crash. Add a NULL pointer check and return -ENOMEM to handle allocation failure properly.
CVE-2024-38651 1 Veeam 1 Service Provider Console 2026-04-15 N/A
A code injection vulnerability can allow a low-privileged user to overwrite files on that VSPC server, which can lead to remote code execution on VSPC server.
CVE-2024-5404 1 Ifm 4 Moneo For Microsoft Windows, Moneo Qha210, Moneo Qha300 and 1 more 2026-04-15 9.8 Critical
An unauthenticated remote attacker can change the admin password in a moneo appliance due to weak password recovery mechanism.
CVE-2025-8870 1 Arista 1 Eos 2026-04-15 4.9 Medium
On affected platforms running Arista EOS, certain serial console input might result in an unexpected reload of the device.153
CVE-2024-5403 2026-04-15 7.2 High
ASKEY 5G NR Small Cell fails to properly filter user input for certain functionality, allowing remote attackers with administrator privilege to execute arbitrary system commands on the remote server.
CVE-2025-53545 2026-04-15 N/A
Press, a Frappe custom app that runs Frappe Cloud, manages infrastructure, subscription, marketplace, and software-as-a-service (SaaS). Users can circumvent 2FA login for users due to a lack of server side validation for the same. This vulnerability is fixed in commit ddb439f8eb1816010f2ef653a908648b71f9bba8.
CVE-2024-54015 2026-04-15 7.5 High
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7KE85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SA87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SS85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7ST85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7ST85 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) V9.8x (All versions < V9.83), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VK87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions >= V8.80 < V9.90), SIPROTEC 5 Communication Module ETH-BD-2FO V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BD-2FO V9.8 (All versions < V9.83), SIPROTEC 5 Compact 7SX800 (CP050) (All versions >= V9.50 < V9.90). Affected devices do not properly validate SNMP GET requests. This could allow an unauthenticated, remote attacker to retrieve sensitive information of the affected devices with SNMPv2 GET requests using default credentials.
CVE-2025-1979 2026-04-15 6.4 Medium
Versions of the package ray before 2.43.0 are vulnerable to Insertion of Sensitive Information into Log File where the redis password is being logged in the standard logging. If the redis password is passed as an argument, it will be logged and could potentially leak the password. This is only exploitable if: 1) Logging is enabled; 2) Redis is using password authentication; 3) Those logs are accessible to an attacker, who can reach that redis instance. **Note:** It is recommended that anyone who is running in this configuration should update to the latest version of Ray, then rotate their redis password.
CVE-2024-6003 2026-04-15 7.3 High
A vulnerability was found in Guangdong Baolun Electronics IP Network Broadcasting Service Platform 2.0. It has been classified as critical. Affected is an unknown function of the file /api/v2/maps. The manipulation of the argument orderColumn leads to sql injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-268692. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.