Search Results (806 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-46505 2026-04-15 9.1 Critical
Infoblox BloxOne v2.4 was discovered to contain a business logic flaw due to thick client vulnerabilities.
CVE-2024-28327 1 Asus 1 Rt-n12\+ B1 2026-04-15 8.4 High
Asus RT-N12+ B1 router stores user passwords in plaintext, which could allow local attackers to obtain unauthorized access and modify router settings.
CVE-2025-2181 1 Paloaltonetworks 1 Checkov 2026-04-15 N/A
A sensitive information disclosure vulnerability in Palo Alto Networks Checkov by Prisma® Cloud can result in the cleartext exposure of Prisma Cloud access keys in Checkov's output.
CVE-2025-41647 2026-04-15 5.5 Medium
A local, low-privileged attacker can learn the password of the connected controller in PLC Designer V4 due to an incorrect implementation that results in the password being displayed in plain text under special conditions.
CVE-2025-2922 2026-04-15 2 Low
A vulnerability classified as problematic was found in Netis WF-2404 1.1.124EN. Affected by this vulnerability is an unknown functionality of the component BusyBox Shell. The manipulation leads to cleartext storage of sensitive information. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2023-46294 1 Teledyne 1 Flir M300 2026-04-15 3.4 Low
An issue was discovered in Teledyne FLIR M300 2.00-19. User account passwords are encrypted locally, and can be decrypted to cleartext passwords using the utility umSetup. This utility requires root permissions to execute.
CVE-2025-40753 1 Siemens 2 Q100, Q200 2026-04-15 6.2 Medium
A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices export the password for the SMTP account as plain text in the Configuration File. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes.
CVE-2025-53758 2026-04-15 N/A
This vulnerability exists in Digisol DG-GR6821AC Router due to use of default admin credentials at its web management interface. An attacker with physical access could exploit this vulnerability by extracting the firmware and reverse engineer the binary data to access the hardcoded default credentials stored in the firmware of the targeted device. Successful exploitation of this vulnerability could allow the attacker to gain unauthorized access to the targeted device.
CVE-2024-45718 2026-04-15 4.6 Medium
Sensitive data could be exposed to non- privileged users in a configuration file. Local access to the computer with a low- privileged account is required to access the configuration file containing the sensitive data.
CVE-2025-59102 1 Dormakaba 1 Access Manager 2026-04-15 N/A
The web server of the Access Manager offers a functionality to download a backup of the local database stored on the device. This database contains the whole configuration. This includes encrypted MIFARE keys, card data, user PINs and much more. The PINs are even stored unencrypted. Combined with the fact that an attacker can easily get access to the backup functionality by abusing the session management issue (CVE-2025-59101), or by exploiting the weak default password (CVE-2025-59108), or by simply setting a new password without prior authentication via the SOAP API (CVE-2025-59097), it is easily possible to access the sensitive data on the device.
CVE-2024-23942 2026-04-15 7.1 High
A local user may find a configuration file on the client workstation with unencrypted sensitive data. This allows an attacker to impersonate the device or prevent the device from accessing the cloud portal which leads to a DoS.
CVE-2024-51175 2026-04-15 7.5 High
An issue in H3C switch h3c-S1526 allows a remote attacker to obtain sensitive information via the S1526.cfg component.
CVE-2024-53979 1 Ibm 1 Zhmc 2026-04-15 8.3 High
ibm.ibm_zhmc is an Ansible collection for the IBM Z HMC. The Ansible collection "ibm.ibm_zhmc" writes password-like properties in clear text into its log file and into the output returned by some of its Ansible module in the following cases: 1. The 'boot_ftp_password' and 'ssc_master_pw' properties are passed as input to the zhmc_partition Ansible module. 2. The 'ssc_master_pw' and 'zaware_master_pw' properties are passed as input to the zhmc_lpar Ansible module. 3. The 'password' property is passed as input to the zhmc_user Ansible module (just in log file, not in module output). 4. The 'bind_password' property is passed as input to the zhmc_ldap_server_definition Ansible module. These properties appear in the module output only when they were specified in the module input and when creating or updating the corresponding resources. They do not appear in the output when retrieving facts for the corresponding resources. These properties appear in the log file only when the "log_file" module input parameter is used. By default, no log file is created. This issue has been fixed in ibm.ibm_zhmc version 1.9.3. Users are advised to upgrade. There are no known workarounds for this vulnerability.
CVE-2024-36497 1 Faronics 1 Winselect 2026-04-15 9.1 Critical
The decrypted configuration file contains the password in cleartext which is used to configure WINSelect. It can be used to remove the existing restrictions and disable WINSelect entirely.
CVE-2024-39846 2026-04-15 3.5 Low
NewPass before 1.2.0 stores passwords (rather than password hashes) directly, which makes it easier to obtain unauthorized access to sensitive information. NOTE: in each case, data at rest is encrypted, but is decrypted within process memory during use.
CVE-2025-0142 2026-04-15 4.3 Medium
Cleartext storage of sensitive information in the Zoom Jenkins Marketplace plugin before version 1.4 may allow an authenticated user to conduct a disclosure of information via network access.
CVE-2025-40752 1 Siemens 2 Q100, Q200 2026-04-15 6.2 Medium
A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices store the password for the SMTP account as plain text. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes.
CVE-2025-59450 1 Yosmart 1 Yolink Smart Hub 2026-04-15 4.3 Medium
The YoSmart YoLink Smart Hub firmware 0382 is unencrypted, and data extracted from it can be used to determine network access credentials.
CVE-2025-2909 2026-04-15 N/A
The lack of encryption in the DuoxMe (formerly Blue) application binary in versions prior to 3.3.1 for iOS devices allows an attacker to gain unauthorised access to the application code and discover sensitive information.
CVE-2025-4394 2026-04-15 6.8 Medium
Medtronic MyCareLink Patient Monitor uses an unencrypted filesystem on internal storage, which allows an attacker with physical access to read and modify files. This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025