Filtered by vendor Siemens Subscriptions
Total 2221 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2024-35207 1 Siemens 1 Sinec Traffic Analyzer 2024-11-21 7.8 High
A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V1.2). The web interface of the affected devices are vulnerable to Cross-Site Request Forgery(CSRF) attacks. By tricking an authenticated victim user to click a malicious link, an attacker could perform arbitrary actions on the device on behalf of the victim user.
CVE-2024-33654 1 Siemens 1 Simcenter Femap 2024-11-21 7.8 High
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process.
CVE-2024-33653 1 Siemens 1 Simcenter Femap 2024-11-21 7.8 High
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process.
CVE-2024-33583 1 Siemens 1 Simatic Rtls Locating Manager 2024-11-21 3.3 Low
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). Affected application contains a hidden configuration item to enable debug functionality. This could allow an authenticated local attacker to gain insight into the internal configuration of the deployment.
CVE-2024-32639 1 Siemens 1 Tecnomatix Plant Simulation 2024-11-21 7.8 High
A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0011). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted MODEL file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-22974)
CVE-2024-24925 1 Siemens 1 Simcenter Femap 2024-11-21 7.8 High
A vulnerability has been identified in Simcenter Femap (All versions < V2306.0000). The affected application is vulnerable to uninitialized pointer access while parsing specially crafted Catia MODEL files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-22060)
CVE-2024-24920 1 Siemens 1 Simcenter Femap 2024-11-21 7.8 High
A vulnerability has been identified in Simcenter Femap (All versions < V2401.0000). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted Catia MODEL file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21710)
CVE-2024-23812 1 Siemens 1 Sinec Nms 2024-11-21 8 High
A vulnerability has been identified in SINEC NMS (All versions < V2.0 SP1). The affected application incorrectly neutralizes special elements when creating a report which could lead to command injection.
CVE-2024-23811 1 Siemens 1 Sinec Nms 2024-11-21 8.8 High
A vulnerability has been identified in SINEC NMS (All versions < V2.0 SP1). The affected application allows users to upload arbitrary files via TFTP. This could allow an attacker to upload malicious firmware images or other files, that could potentially lead to remote code execution.
CVE-2024-23804 1 Siemens 1 Tecnomatix Plant Simulation 2024-11-21 7.8 High
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant Simulation V2302 (All versions < V2302.0006). The affected applications contain a stack overflow vulnerability while parsing specially crafted PSOBJ files. This could allow an attacker to execute code in the context of the current process.
CVE-2024-23801 1 Siemens 1 Tecnomatix Plant Simulation 2024-11-21 3.3 Low
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V2302 (All versions < V2302.0007). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted SPP files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.
CVE-2024-23800 1 Siemens 1 Tecnomatix Plant Simulation 2024-11-21 3.3 Low
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V2302 (All versions < V2302.0007). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted SPP files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.
CVE-2024-23799 1 Siemens 1 Tecnomatix Plant Simulation 2024-11-21 3.3 Low
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V2302 (All versions < V2302.0007). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted SPP files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.
CVE-2024-23798 1 Siemens 1 Tecnomatix Plant Simulation 2024-11-21 7.8 High
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant Simulation V2302 (All versions < V2302.0006). The affected applications contain a stack overflow vulnerability while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
CVE-2024-23797 1 Siemens 1 Tecnomatix Plant Simulation 2024-11-21 7.8 High
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant Simulation V2302 (All versions < V2302.0006). The affected applications contain a stack overflow vulnerability while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
CVE-2024-23796 1 Siemens 1 Tecnomatix Plant Simulation 2024-11-21 7.8 High
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant Simulation V2302 (All versions < V2302.0006). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
CVE-2024-22045 1 Siemens 1 Sinema Remote Connect Client 2024-11-21 7.6 High
A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.1 SP1). The product places sensitive information into files or directories that are accessible to actors who are allowed to have access to the files, but not to the sensitive information. This information is also available via the web interface of the product.
CVE-2024-22043 1 Siemens 1 Parasolid 2024-11-21 3.3 Low
A vulnerability has been identified in Parasolid V35.0 (All versions < V35.0.251), Parasolid V35.1 (All versions < V35.1.170). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted XT files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.
CVE-2023-51746 1 Siemens 2 Jt2go, Teamcenter Visualization 2024-11-21 7.8 High
A vulnerability has been identified in JT2Go (All versions < V14.3.0.6), Teamcenter Visualization V13.3 (All versions < V13.3.0.13), Teamcenter Visualization V14.1 (All versions < V14.1.0.12), Teamcenter Visualization V14.2 (All versions < V14.2.0.9), Teamcenter Visualization V14.3 (All versions < V14.3.0.6). The affected applications contain a stack overflow vulnerability while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process.
CVE-2023-49692 1 Siemens 40 6gk5615-0aa00-2aa2, 6gk5615-0aa00-2aa2 Firmware, 6gk5615-0aa01-2aa2 and 37 more 2024-11-21 7.2 High
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V7.2.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V7.2.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V7.2.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V7.2.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V7.2.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V7.2.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V7.2.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V7.2.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V7.2.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V7.2.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V7.2.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V7.2.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V7.2.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V7.2.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V7.2.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V7.2.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V7.2.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V7.2.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V7.2.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V7.2.2). An Improper Neutralization of Special Elements used in an OS Command with root privileges vulnerability exists in the parsing of the IPSEC configuration. This could allow malicious local administrators to issue commands on system level after a new connection is established.