| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An issue was discovered on the Audi Universal Traffic Recorder 2.88. It has Susceptibility to denial of service. It uses the same default credentials for all devices and does not implement proper multi-device authentication, allowing attackers to deny the owner access by occupying the only available connection. The SSID remains broadcast at all times, increasing exposure to potential attacks. |
| Sangoma FreePBX 1805 through 2203 on Linux contains hardcoded credentials for the Asterisk REST Interface (ARI), which allows remote attackers to reconfigure Asterisk and make external and internal calls via HTTP and WebSocket requests sent to the API. |
| MinMax CMS from MinMax Digital Technology contains a hidden administrator account with a fixed password that cannot be removed or disabled from the management interface. Remote attackers who obtain this account can bypass IP access control restrictions and log in to the backend system without being recorded in the system logs. |
| Hard-coded cryptographic keys in Admin UI of EZCast Pro II version 1.17478.146 allows attackers to bypass authorization checks and gain full access to the admin UI |
| Heatmiser Netmonitor 3.03 contains a hardcoded credentials vulnerability in the networkSetup.htm page with predictable admin login credentials. Attackers can access the device by using the hard-coded username 'admin' and password 'admin' in the hidden form input fields. |
| The ArchiverSpaApi ASP.NET application uses a hard-coded JWT signing key. An unauthenticated remote attacker can generate and use a verifiable JWT token to access protected ArchiverSpaApi URL endpoints. |
| In the IROAD APK 5.2.5, there are Hardcoded Credentials in the APK for ports 9091 and 9092. The mobile application for the dashcam contains hardcoded credentials that allow an attacker on the local Wi-Fi network to access API endpoints and retrieve sensitive device information, including live and recorded footage. |
| The Clinician Password and Serial Number Clinician Password are hard-coded into the ventilator in plaintext form. This could allow an attacker to obtain the password off the ventilator and use it to gain unauthorized access to the device, with clinician privileges. |
| The program libraries (DLL) and binaries used by exos 9300 contain multiple hard-coded secrets. One notable example is the function "EncryptAndDecrypt" in the library Kaba.EXOS.common.dll. This algorithm uses a simple XOR encryption technique combined with a cryptographic key (cryptoKey) to transform each character of the input string. However, it's important to note that this implementation does not provide strong encryption and should not be considered secure for sensitive data. It's more of a custom encryption approach rather than a common algorithm used in cryptographic applications. The key itself is static and based on the founder's name of the company. The functionality is for example used to encrypt the user PINs before storing them in the MSSQL database. |
| The firmware of all Wattsense Bridge devices contain the same hard-coded user and root credentials. The user password can be easily recovered via password cracking attempts. The recovered credentials can be used to log into the device via the login shell that is exposed by the serial interface. The backdoor user has been removed in firmware BSP >= 6.4.1. |
| The firmware in KAON CG3000TC and CG3000T routers contains hard-coded credentials in clear text (shared across all routers of this model) that an unauthenticated remote attacker could use to execute commands with root privileges.
This vulnerability has been fixed in firmware version: 1.00.67 for CG3000TC and 1.00.27 for CG3000T. |
| DCIM dcTrack platforms utilize default and hard-coded credentials for access. An attacker could use these credentials to administer the database, escalate privileges on the platform or execute system commands on the host. |
| SQL Anywhere Monitor (Non-GUI) baked credentials into the code,exposing the resources or functionality to unintended users and providing attackers with the possibility of arbitrary code execution.This could cause high impact on confidentiality integrity and availability of the system. |
| A vulnerability was found in shsuishang ShopSuite ModulithShop up to 45a99398cec3b7ad7ff9383694f0b53339f2d35a. Affected by this issue is some unknown functionality of the component RSA/OAuth2/Database. The manipulation results in hard-coded credentials. The attack can be executed remotely. The exploit has been made public and could be used. This product implements a rolling release for ongoing delivery, which means version information for affected or updated releases is unavailable. |
| A predefined administrative account is not documented and cannot
be deactivated. This account cannot be misused from the network, only by local
users on the server. |
| Aptos Wisal payroll accounting before 7.1.6 uses hardcoded credentials in the Windows client to fetch the complete list of usernames and passwords from the database server, using an unencrypted connection. This allows attackers in a machine-in-the-middle position read and write access to personally identifiable information (PII) and especially payroll data and the ability to impersonate legitimate users with respect to the audit log. |
| A vulnerability in the .sdd file allows an attacker to read default passwords stored in plain text within the code. By exploiting these plaintext credentials, an attacker can log into affected SICK products as an “Authorized Client” if the customer has not changed the default password. |
| API keys for some cloud services are hardcoded in the "main" binary. As for the details of affected product names, model numbers, and versions, refer to the information provided by the respective vendors listed under [References]. |
| Ecovacs Home Android and iOS Mobile Applications up to version 3.3.0 contained embedded access keys and secrets for Alibaba Object Storage Service (OSS), leading to sensitive data disclosure. |
| An issue was discovered on Marbella KR8s Dashcam FF 2.0.8 devices. All dashcams were shipped with the same default credentials of 12345678, which creates an insecure-by-default condition. For users who change their passwords, it's limited to 8 characters. These short passwords can be cracked in 8 hours via low-end commercial cloud resources. |