Filtered by CWE-489
Total 70 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2025-52663 1 Ui 2 Unifi Os, Unifi Talk 2025-12-02 7.3 High
A vulnerability was identified in certain UniFi Talk devices where internal debugging functionality remained unintentionally enabled. This issue could allow an attacker with access to the UniFi Talk management network to invoke internal debug operations through the device API. Affected Products: UniFi Talk Touch (Version 1.21.16 and earlier) UniFi Talk Touch Max (Version 2.21.22 and earlier) UniFi Talk G3 Phones (Version 3.21.26 and earlier) Mitigation: Update the UniFi Talk Touch to Version 1.21.17 or later. Update the UniFi Talk Touch Max to Version 2.21.23 or later. Update the UniFi Talk G3 Phones to Version 3.21.27 or later.
CVE-2025-64983 1 Switchbot 1 Smart Video Doorbell 2025-12-01 N/A
Smart Video Doorbell firmware versions prior to 2.01.078 contain an active debug code vulnerability that allows an attacker to connect via Telnet and gain access to the device.
CVE-2025-2486 2 Canonical, Ubuntu 3 Ubuntu, Edk2, Ubuntu 2025-12-01 N/A
The Ubuntu edk2 UEFI firmware packages accidentally allowed the UEFI Shell to be accessed in Secure Boot environments, possibly allowing bypass of Secure Boot constraints. Versions 2024.05-2ubuntu0.3 and 2024.02-2ubuntu0.3 disable the Shell. Some previous versions inserted a secure-boot-based decision to continue running inside the Shell itself, which is believed to be sufficient to enforce Secure Boot restrictions. This is an additional repair on top of the incomplete fix for CVE-2023-48733.
CVE-2024-9643 1 Four-faith 3 F3x24, F3x36, F3x36 Firmware 2025-11-22 9.8 Critical
The Four-Faith F3x36 router using firmware v2.0.0 is vulnerable to authentication bypass due to hard-coded credentials in the administrative web server. An attacker with knowledge of the credentials can gain administrative access via crafted HTTP requests. This issue appears similar to CVE-2023-32645.
CVE-2025-54660 1 Fortinet 2 Forticlient, Forticlientwindows 2025-11-20 4.9 Medium
An active debug code vulnerability in Fortinet FortiClientWindows 7.4.0 through 7.4.3, FortiClientWindows 7.2.0 through 7.2.10, FortiClientWindows 7.0 all versions may allow a local attacker to run the application step by step and retrieve the saved VPN user password
CVE-2024-9644 1 Four-faith 2 F3x36, F3x36 Firmware 2025-11-19 9.8 Critical
The Four-Faith F3x36 router using firmware v2.0.0 is vulnerable to an authentication bypass vulnerability in the administrative web server. Authentication is not enforced on some administrative functionality when using the "bapply.cgi" endpoint instead of the normal "apply.cgi" endpoint. A remote and unauthenticated can use this vulnerability to modify settings or chain with existing authenticated vulnerabilities.
CVE-2025-30185 1 Intel 1 Reference Server Platforms 2025-11-14 7.9 High
Active debug code for some Intel UEFI reference platforms within Ring 0: Kernel may allow a denial of service and escalation of privilege. System software adversary with a privileged user combined with a low complexity attack may enable data alteration. This result may potentially occur via local access when attack requirements are not present without special internal knowledge and requires no user interaction. The potential vulnerability may impact the confidentiality (none), integrity (high) and availability (high) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (high) and availability (high) impacts.
CVE-2024-53648 2025-11-11 6.8 Medium
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions < V9.90), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions < V9.90), SIPROTEC 5 6MU85 (CP300) (All versions < V9.90), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions < V10.0), SIPROTEC 5 7SA82 (CP100) (All versions < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions < V9.90), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions < V9.90), SIPROTEC 5 7SD82 (CP100) (All versions < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions < V9.90), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions < V9.90), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions < V9.90), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions < V9.90), SIPROTEC 5 7SK82 (CP100) (All versions < V8.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions < V9.90), SIPROTEC 5 7SL82 (CP100) (All versions < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions < V9.90), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions < V9.90), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions < V9.90), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions < V9.90), SIPROTEC 5 7UT82 (CP100) (All versions < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions < V9.90), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions < V9.90), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions < V9.90), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.90). Affected devices do not properly limit access to a development shell accessible over a physical interface. This could allow an unauthenticated attacker with physical access to the device to execute arbitrary commands on the device.
CVE-2023-34346 1 Yifanwireless 2 Yf325, Yf325 Firmware 2025-11-04 9.8 Critical
A stack-based buffer overflow vulnerability exists in the httpd gwcfg.cgi get functionality of Yifan YF325 v1.0_20221108. A specially crafted network packet can lead to command execution. An attacker can send a network request to trigger this vulnerability.
CVE-2023-32645 1 Yifanwireless 2 Yf325, Yf325 Firmware 2025-11-04 9.8 Critical
A leftover debug code vulnerability exists in the httpd debug credentials functionality of Yifan YF325 v1.0_20221108. A specially crafted network request can lead to authentication bypass. An attacker can send a network request to trigger this vulnerability.
CVE-2024-21827 1 Tp-link 2 Er7206, Er7206 Firmware 2025-11-04 7.2 High
A leftover debug code vulnerability exists in the cli_server debug functionality of Tp-Link ER7206 Omada Gigabit VPN Router 1.4.1 Build 20240117 Rel.57421. A specially crafted series of network requests can lead to arbitrary command execution. An attacker can send a sequence of requests to trigger this vulnerability.
CVE-2023-49593 2 Level1, Level One 3 Wbr-6013, Wbr-6013 Firmware, Wbr6013 2025-11-04 7.2 High
Leftover debug code exists in the boa formSysCmd functionality of LevelOne WBR-6013 RER4_A_v3411b_2T2R_LEV_09_170623. A specially crafted network request can lead to arbitrary command execution.
CVE-2025-4106 1 Watchguard 1 Fireware 2025-10-28 N/A
An authenticated admin user with access to both the management WebUI and command line interface on a Firebox can enable a diagnostic debug shell by uploading a platform and version-specific diagnostic package and executing a leftover diagnostic command. This issue affects Fireware OS: from 12.0 before 12.11.2.
CVE-2024-28008 1 Nec 118 Aterm Cr2500p, Aterm Cr2500p Firmware, Aterm Mr01ln and 115 more 2025-09-29 9.8 Critical
Active Debug Code in NEC Corporation Aterm WG1800HP4, WG1200HS3, WG1900HP2, WG1200HP3, WG1800HP3, WG1200HS2, WG1900HP, WG1200HP2, W1200EX(-MS), WG1200HS, WG1200HP, WF300HP2, W300P, WF800HP, WR8165N, WG2200HP, WF1200HP2, WG1800HP2, WF1200HP, WG600HP, WG300HP, WF300HP, WG1800HP, WG1400HP, WR8175N, WR9300N, WR8750N, WR8160N, WR9500N, WR8600N, WR8370N, WR8170N, WR8700N, WR8300N, WR8150N, WR4100N, WR4500N, WR8100N, WR8500N, CR2500P, WR8400N, WR8200N, WR1200H, WR7870S, WR6670S, WR7850S, WR6650S, WR6600H, WR7800H, WM3400RN, WM3450RN, WM3500R, WM3600R, WM3800R, WR8166N, MR01LN MR02LN, WG1810HP(JE) and WG1810HP(MF) all versions allows a attacker to execute an arbitrary OS command via the internet.
CVE-2024-44092 1 Google 1 Android 2025-09-15 7.8 High
There is a possible LCS signing enforcement missing due to test/debugging code left in a production build. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.
CVE-2025-36899 1 Google 1 Android 2025-09-05 8.4 High
There is a possible escalation of privilege due to test/debugging code left in a production build. This could lead to physical escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.
CVE-2024-30219 1 Planex 4 Mzk-mf300hp2, Mzk-mf300hp2 Firmware, Mzk-mf300n and 1 more 2025-08-27 6.8 Medium
Active debug code vulnerability exists in PLANEX COMMUNICATIONS wireless LAN routers. If a logged-in user who knows how to use the debug function accesses the device's management page, an unintended operation may be performed. Note that MZK-MF300N is no longer supported, therefore the update for this product is not provided.
CVE-2025-21472 1 Qualcomm 25 Fastconnect 6900, Fastconnect 6900 Firmware, Fastconnect 7800 and 22 more 2025-08-18 5.5 Medium
Information disclosure while capturing logs as eSE debug messages are logged.
CVE-2024-32047 1 Cyberpower 2 Powerpanel, Powerpanel Business 2025-07-30 9.8 Critical
Hard-coded credentials for the CyberPower PowerPanel test server can be found in the production code. This might result in an attacker gaining access to the testing or production server.
CVE-2025-7705 2025-07-22 6.8 Medium
: Active Debug Code vulnerability in ABB Switch Actuator 4 DU-83330, ABB Switch actuator, door/light 4 DU -83330-500.This issue affects Switch Actuator 4 DU-83330: All Versions; Switch actuator, door/light 4 DU -83330-500: All Versions.